Literature DB >> 12972083

Near-infrared spectroscopy for the determination of testosterone in thin-film composites.

William Fountain1, Karen Dumstorf, Amanda E Lowell, Robert A Lodder, Russell J Mumper.   

Abstract

More rapid, reproducible, and cost-effective methods to control product quality in the pharmaceutical industry continue to be a major emphasis, particularly with the FDA through its recent process analytical technologies (PAT) initiative. Many different methods have been used to determine the stability and content uniformity of a drug in various dosage forms; however, most of these methods include the destruction of the sample. Therefore, the development of nondestructive methods that allow the analysis of each individual dosage form has become the basis of much research. A new assay for the nondestructive determination of testosterone content in mucoadhesive bi-layer thin-film composites (TFCs) using near-infrared spectroscopy (NIR) was developed. Five sets of the circular films (n=5) with theoretical testosterone content of 0, 1, 2, 3, and 4 mg per 3/8th in. diameter disks were scanned in the near-infrared region of 1100-2500 nm to determine testosterone content. The NIR results were directly compared with those obtained using a previously developed ultraviolet assay for testosterone at 240 nm. Principal component regression (PCR) was performed to calibrate the NIR assay. This correlation produced r2=0.99 with a standard error of estimate (SEE)=0.18 mg, and a standard error of performance (SEP)=0.18 on cross validation with an equal number of samples (F test passed at P=0.05). Though the UV assay showed a slightly better r2 value, the NIR assay was much quicker, easier, and nondestructive. Therefore, the NIR assay may have significant potential for use in the quality control of pharmaceutical films containing drugs.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12972083     DOI: 10.1016/s0731-7085(03)00345-5

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Wet granulation in rotary processor and fluid bed: comparison of granule and tablet properties.

Authors:  Jakob Kristensen; Vibeke Wallaert Hansen
Journal:  AAPS PharmSciTech       Date:  2006-03-10       Impact factor: 3.246

2.  Near infrared spectrometry for the quantification of human dermal absorption of econazole nitrate and estradiol.

Authors:  Joseph P Medendorp; Kalpana S Paudel; Robert A Lodder; Audra L Stinchcomb
Journal:  Pharm Res       Date:  2006-11-14       Impact factor: 4.200

3.  Spectral pattern of urinary water as a biomarker of estrus in the giant panda.

Authors:  Kodzue Kinoshita; Mari Miyazaki; Hiroyuki Morita; Maria Vassileva; Chunxiang Tang; Desheng Li; Osamu Ishikawa; Hiroshi Kusunoki; Roumiana Tsenkova
Journal:  Sci Rep       Date:  2012-11-22       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.