Literature DB >> 16584144

Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part I, product temperature measurement.

Xiaolin Tang1, Steven L Nail, Michael J Pikal.   

Abstract

This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperature, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45 degrees C).

Mesh:

Year:  2006        PMID: 16584144      PMCID: PMC2750721          DOI: 10.1208/pt070114

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  8 in total

Review 1.  Design of freeze-drying processes for pharmaceuticals: practical advice.

Authors:  Xiaolin Tang; Michael J Pikal
Journal:  Pharm Res       Date:  2004-02       Impact factor: 4.200

2.  Freeze-drying process design by manometric temperature measurement: design of a smart freeze-dryer.

Authors:  Xiaolin Charlie Tang; Steven L Nail; Michael J Pikal
Journal:  Pharm Res       Date:  2005-04       Impact factor: 4.200

3.  Evaluation of manometric temperature measurement as a method of monitoring product temperature during lyophilization.

Authors:  N Milton; M J Pikal; M L Roy; S L Nail
Journal:  PDA J Pharm Sci Technol       Date:  1997 Jan-Feb

Review 4.  Rational design of stable lyophilized protein formulations: some practical advice.

Authors:  J F Carpenter; M J Pikal; B S Chang; T W Randolph
Journal:  Pharm Res       Date:  1997-08       Impact factor: 4.200

5.  Process control in freeze drying: determination of the end point of sublimation drying by an electronic moisture sensor.

Authors:  M L Roy; M J Pikal
Journal:  J Parenter Sci Technol       Date:  1989 Mar-Apr

6.  Mass and heat transfer in vial freeze-drying of pharmaceuticals: role of the vial.

Authors:  M J Pikal; M L Roy; S Shah
Journal:  J Pharm Sci       Date:  1984-09       Impact factor: 3.534

7.  Use of laboratory data in freeze drying process design: heat and mass transfer coefficients and the computer simulation of freeze drying.

Authors:  M J Pikal
Journal:  J Parenter Sci Technol       Date:  1985 May-Jun

8.  Physical chemistry of freeze-drying: measurement of sublimation rates for frozen aqueous solutions by a microbalance technique.

Authors:  M J Pikal; S Shah; D Senior; J E Lang
Journal:  J Pharm Sci       Date:  1983-06       Impact factor: 3.534

  8 in total
  4 in total

1.  Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part II measurement of dry-layer resistance.

Authors:  Xiaolin Charlie Tang; Steven L Nail; Michael J Pikal
Journal:  AAPS PharmSciTech       Date:  2006       Impact factor: 3.246

2.  Evaluation of manometric temperature measurement (MTM), a process analytical technology tool in freeze drying, part III: heat and mass transfer measurement.

Authors:  Xiaolin Charlie Tang; Steven L Nail; Michael J Pikal
Journal:  AAPS PharmSciTech       Date:  2006       Impact factor: 3.246

3.  A QbD case study: Bayesian prediction of lyophilization cycle parameters.

Authors:  Linas Mockus; David LeBlond; Prabir K Basu; Rakhi B Shah; Mansoor A Khan
Journal:  AAPS PharmSciTech       Date:  2011-03-04       Impact factor: 3.246

4.  Cycle Development in a Mini-Freeze Dryer: Evaluation of Manometric Temperature Measurement in Small-Scale Equipment.

Authors:  Tim Wenzel; Margit Gieseler; Ahmad M Abdul-Fattah; Henning Gieseler
Journal:  AAPS PharmSciTech       Date:  2021-04-26       Impact factor: 3.246

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.