Literature DB >> 16581420

Prospective intrapatient comparison of 6.0-millimeter optic single-piece and 3-piece hydrophobic acrylic foldable intraocular lenses.

Ryohei Nejima1, Takashi Miyai, Yasushi Kataoka, Kazunori Miyata, Masato Honbou, Tadatoshi Tokunaga, Keisuke Kawana, Takahiro Kiuchi, Tetsuro Oshika.   

Abstract

PURPOSE: To compare postoperative performance and stability of 6.0-mm optic single- and 3-piece acrylic foldable intraocular lenses (IOLs).
DESIGN: Prospective, randomized, self-controlled trial. PARTICIPANTS: Eighty eyes of 40 patients with bilateral senile cataracts. INTERVENTION: Phacoemulsification and IOL implantation were performed. One eye of a patient was randomly assigned to the SA60AT single-piece IOL, and the contralateral eye was allocated to the MA60AC 3-piece IOL. MAIN OUTCOME MEASURES: Best-corrected visual acuity (BCVA), spherical equivalent, aqueous flare intensity, anterior chamber depth, amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification (PCO) were measured 2 days, 1 week, and 1, 3, 6, and 12 months after surgery. Specular microscopy was performed at 12 months postoperatively.
RESULTS: In the SA60AT group, the anterior chamber depth did not show significant changes after surgery (P>0.05; paired t test), and the refraction remained highly stable throughout the 1-year study period. The MA60AC group showed significant shallowing of the anterior chamber (P<0.05) and a myopic shift (P<0.05) up to 1 month after surgery. There were no significant differences between the 2 groups (P>0.05) in BCVA, aqueous flare intensity, the amount of IOL decentration, IOL tilt, area of anterior capsule opening, and degree of PCO throughout the 12-month follow-up period.
CONCLUSIONS: Both the SA60AT single-piece and MA60AC 3-piece lenses showed a minimum amount of decentration, tilt, anterior capsule contraction, and PCO. Although the MA60AC showed significant forward shift and myopic refractive changes after surgery, the SA60AT displayed little axial movement associated with highly stable refraction after surgery. This feature of the SA60AT should facilitate earlier spectacle prescription and quicker visual/social rehabilitation of patients after cataract surgery.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16581420     DOI: 10.1016/j.ophtha.2005.10.064

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  18 in total

1.  Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients.

Authors:  Ling Bai; Jin Zhang; Ling Chen; Ting Ma; Hou-Cheng Liang
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Temporary changes of visual outcomes and anterior chamber parameters after phacoemulsification and low-add-power segmented intraocular lens implantation for primary angle closure disease.

Authors:  Yohei Chikaraishi; Yoshikuni Arakaki; Hideki Koizumi
Journal:  Int Ophthalmol       Date:  2021-03-22       Impact factor: 2.031

3.  Investigation of the stability of one-piece acrylic intraocular lenses in cataract surgery and in combined vitrectomy surgery.

Authors:  T Iwase; K Sugiyama
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

4.  [Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Authors:  A Frings; I Steinbrugger; E Wissiak; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Ophthalmologe       Date:  2012-06       Impact factor: 1.059

Review 5.  Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.

Authors:  Sophie Maedel; Jennifer R Evans; Annette Harrer-Seely; Oliver Findl
Journal:  Cochrane Database Syst Rev       Date:  2021-08-16

6.  Influences of anterior capsule polishing on effective lens position after cataract surgery: a randomized controlled trial.

Authors:  Yang Gao; Guang-Fu Dang; Xu Wang; Lian Duan; Xin-Yi Wu
Journal:  Int J Clin Exp Med       Date:  2015-08-15

7.  Visual performance of the Tecnis one-piece lens ZCB00.

Authors:  Sherein S Wahba; Riad F Riad; Fathy F Morkos; Abdallah K Hassouna; Maged M Roshdy
Journal:  Clin Ophthalmol       Date:  2011-12-23

8.  Personal A-constant in relation to axial length with various intraocular lenses.

Authors:  Mohamed A Eldaly; Khaled A Mansour
Journal:  Indian J Ophthalmol       Date:  2014-07       Impact factor: 1.848

9.  Comparison of Nd: YAG capsulotomy rate between 1-piece and 3-piece acrylic intraocular lenses: A STROBE-compliant article.

Authors:  Sun Young Kim; Young Kwon Chung; Hye Young Shin; Mee Yon Lee; Young-Chun Lee; Su-Young Kim
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

10.  Altered stress field of the human lens capsule after cataract surgery.

Authors:  Caleb C Berggren; Kurt A Ameku; Ryan M Pedrigi
Journal:  J Biomech       Date:  2020-11-10       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.