Literature DB >> 16570235

Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes.

D Deiss1, R Hartmann, J Schmidt, O Kordonouri.   

Abstract

OBJECTIVE: To study the feasibility and the influence on glycaemic control of continuous glucose monitoring (CGMS) in young patients with type 1 diabetes. DESIGN AND METHODS: A double-blinded, cross-over study was performed in 30 children (median age 11.1 years [range: 2.3 - 16.3], diabetes duration 2.1 years [0.2 - 7.1]). Patients were randomised into an open (A) or blind study arm (B). Both groups performed standardised self-monitoring blood glucose (SMBG) and received CGMS at the beginning of the study, at 3 and 6 months, each. In the blinded arm, patients and investigator were concealed from CGMS data. After 3 months, open and blinded study arms crossed over. Average glucose values and area under the glucose curve (AUC) per 24 h, above 180 and below 60 mg/dl were calculated from CGMS. Haemoglobin A1c (HbA1c) was measured at each study point.
RESULTS: Despite comparable clinical characteristics between the 15 patients of each arm, mean HbA1c was slightly lower in arm A than in B at baseline (7.8 +/- 1.2 % vs. 8.4 +/- 1.1 %, p = 0.148), at 3 months (7.8 +/- 1.1 % vs. 8.3 +/- 1.1 %, p = 0.233), and significantly lower at 6 months (7.6 +/- 1.1 % vs. 8.5 +/- 0.9 %, p = 0.026). However, no significant change of HbA1c occurred within each arm (A, p = 0.183 and B, p = 0.823), irrespectively whether CGMS data were blinded or not. Likewise, mean glucose and hyper- or hypoglycaemia values did not change significantly.
CONCLUSIONS: In this setting, CGMS did not decisively influence glycaemic control of a total study cohort. More frequent use of CGMS at shorter intervals in single patients with hyper- or hypoglycaemic problems may be of greater value than SMBG.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16570235     DOI: 10.1055/s-2006-923887

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  19 in total

Review 1.  Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials.

Authors:  Gunjan Y Gandhi; Michelle Kovalaske; Yogish Kudva; Kristin Walsh; Mohamed B Elamin; Melody Beers; Cathy Coyle; Melissa Goalen; Mohammad Safwan Murad; Patricia J Erwin; Joshua Corpus; Victor M Montori; M Hassan Murad
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

2.  Clinical Use of Continuous Glucose Monitoring in Pediatrics.

Authors:  Rayhan A Lal; David M Maahs
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

3.  A review of current evidence with continuous glucose monitoring in patients with diabetes.

Authors:  Christophe De Block; Begoña Manuel-y-Keenoy; Luc Van Gaal
Journal:  J Diabetes Sci Technol       Date:  2008-07

4.  Glycaemic variability is associated with coronary artery calcium in men with Type 1 diabetes: the Coronary Artery Calcification in Type 1 Diabetes study.

Authors:  J K Snell-Bergeon; R Roman; D Rodbard; S Garg; D M Maahs; I E Schauer; B C Bergman; G L Kinney; M Rewers
Journal:  Diabet Med       Date:  2010-12       Impact factor: 4.359

Review 5.  Exercise and glucose metabolism in persons with diabetes mellitus: perspectives on the role for continuous glucose monitoring.

Authors:  Michael Riddell; Bruce A Perkins
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  Cutaneous Complications With Continuous or Flash Glucose Monitoring Use: Systematic Review of Trials and Observational Studies.

Authors:  Nurul A Mohd Asarani; Andrew N Reynolds; Sara E Boucher; Martin de Bock; Benjamin J Wheeler
Journal:  J Diabetes Sci Technol       Date:  2019-08-27

Review 7.  Technology to optimize pediatric diabetes management and outcomes.

Authors:  Jessica T Markowitz; Kara R Harrington; Lori M B Laffel
Journal:  Curr Diab Rep       Date:  2013-12       Impact factor: 4.810

Review 8.  Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus.

Authors:  Baraka Floyd; Prakash Chandra; Stephanie Hall; Christopher Phillips; Ernest Alema-Mensah; Gregory Strayhorn; Elizabeth O Ofili; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

9.  Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial.

Authors:  M A O'Connell; S Donath; D N O'Neal; P G Colman; G R Ambler; T W Jones; E A Davis; F J Cameron
Journal:  Diabetologia       Date:  2009-04-25       Impact factor: 10.122

Review 10.  Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis.

Authors:  D T Golicki; D Golicka; L Groele; E Pankowska
Journal:  Diabetologia       Date:  2007-12-01       Impact factor: 10.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.