PURPOSE: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. MATERIALS AND METHODS: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. RESULTS: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). CONCLUSION: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value. Copyright 2006 Wiley-Liss, Inc.
PURPOSE: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. MATERIALS AND METHODS: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. RESULTS: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). CONCLUSION: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value. Copyright 2006 Wiley-Liss, Inc.
Authors: John-Paul Carpenter; Taigang He; Paul Kirk; Michael Roughton; Lisa J Anderson; Sofia V de Noronha; Mary N Sheppard; John B Porter; J Malcolm Walker; John C Wood; Renzo Galanello; Gianluca Forni; Gualtiero Catani; Gildo Matta; Suthat Fucharoen; Adam Fleming; Michael J House; Greg Black; David N Firmin; Timothy G St Pierre; Dudley J Pennell Journal: Circulation Date: 2011-03-28 Impact factor: 29.690
Authors: Antonella Meloni; Jon Detterich; Vasili Berdoukas; Alessia Pepe; Massimo Lombardi; Thomas D Coates; John C Wood Journal: Am J Hematol Date: 2013-02-06 Impact factor: 10.047
Authors: Taigang He; Peter D Gatehouse; Gillian C Smith; Raad H Mohiaddin; Dudley J Pennell; David N Firmin Journal: Magn Reson Med Date: 2008-11 Impact factor: 4.668
Authors: Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu Journal: J Magn Reson Imaging Date: 2009-08 Impact factor: 4.813