Literature DB >> 16565797

Percutaneous vertebroplasty for osteoporotic compression fracture: multivariate study of predictors of new vertebral body fracture.

Atsushi Komemushi1, Noboru Tanigawa, Shuji Kariya, Hiroyuki Kojima, Yuzo Shomura, Sadao Komemushi, Satoshi Sawada.   

Abstract

PURPOSE: To investigate the risk factors and relative risk of new compression fractures following vertebroplasty.
METHODS: Initially, we enrolled 104 consecutive patients with vertebral compression fractures caused by osteoporosis. A total of 83 of the 104 patients visited our hospital for follow-up examinations for more than 4 weeks after vertebroplasty. Logistic regression analysis of the data obtained from these 83 patients was used to determine relative risks of recurrent compression fractures, using 13 different factors.
RESULTS: We identified 59 new fractures in 30 of the 83 patients: 41 new fractures in vertebrae adjacent to treated vertebrae; and 18 new fractures in vertebrae not adjacent to treated vertebrae. New fractures occurred in vertebrae adjacent to treated vertebrae significantly more frequently than in vertebrae not adjacent to treated vertebrae. Only cement leakage into the disk was a significant predictor of new vertebral body fracture after vertebroplasty (odds ratio = 4.633). None of the following covariates were associated with increased risk of new fracture: age, gender, bone mineral density, the number of vertebroplasty procedures, the number of vertebrae treated per procedure, the cumulative number of vertebrae treated, the presence of a single untreated vertebra between treated vertebrae, the presence of multiple untreated vertebrae between treated vertebrae, the amount of bone cement injected per procedure, the cumulative amount of bone cement injected, cement leakage into the soft tissue around the vertebra, and cement leakage into the vein.

Entities:  

Mesh:

Year:  2006        PMID: 16565797     DOI: 10.1007/s00270-005-0138-5

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  59 in total

1.  Evaluation of pain reduction and height restoration post vertebral augmentation using a polyether ether ketone (PEEK) polymer implant for the treatment of split (Magerl A2) vertebral fractures: a prospective, long-term, non-randomized study.

Authors:  Georgios Velonakis; Dimitrios Filippiadis; Stavros Spiliopoulos; Elias Brountzos; Nikolaos Kelekis; Alexis Kelekis
Journal:  Eur Radiol       Date:  2018-12-03       Impact factor: 5.315

2.  Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty.

Authors:  Young-Joon Rho; Woo Jin Choe; Young Il Chun
Journal:  Eur Spine J       Date:  2011-12-09       Impact factor: 3.134

3.  Osteoporotic vertebral compression fractures augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINE SUPPORT): a prospective nonrandomized study.

Authors:  Salvatore Masala; Giovanni Nano; Stefano Marcia; Mario Muto; Francesco Paolo Maria Fucci; Giovanni Simonetti
Journal:  Neuroradiology       Date:  2011-08-11       Impact factor: 2.804

4.  Preventive vertebroplasty for adjacent vertebral bodies: a good solution to reduce adjacent vertebral fracture after percutaneous vertebroplasty.

Authors:  C H Yen; M M H Teng; W H Yuan; Y C Sun; C Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-26       Impact factor: 3.825

5.  Vertebral compression fracture with intravertebral vacuum cleft sign: pathogenesis, image, and surgical intervention.

Authors:  Ai-Min Wu; Yong-Long Chi; Wen-Fei Ni
Journal:  Asian Spine J       Date:  2013-05-22

6.  Thoraco-lumbar traumatic vertebral fractures augmentation by osteo-conductive and osteo-inductive bone substitute containing strontium-hydroxyapatite: our experience.

Authors:  Salvatore Masala; Amedeo Taglieri; Antonio Chiaravalloti; Eros Calabria; Marco Morini; Riccardo Iundusi; Umberto Tarantino; Giovanni Simonetti
Journal:  Neuroradiology       Date:  2014-03-21       Impact factor: 2.804

7.  Risk factors of new symptomatic vertebral compression fractures in osteoporotic patients undergone percutaneous vertebroplasty.

Authors:  Hai-long Ren; Jian-ming Jiang; Jian-ting Chen; Ji-xing Wang
Journal:  Eur Spine J       Date:  2015-02-03       Impact factor: 3.134

8.  Vertebroplasty in the treatment of osteoporosis vertebral fractures: report on 52 cases.

Authors:  L Fenoglio; P Cena; E Migliore; C Bracco; D Ferrigno; A Silvestri; G Lingua; G Gollè; C Brignone; C Serraino; G Gallarato; F Pomero; M Grosso
Journal:  J Endocrinol Invest       Date:  2008-09       Impact factor: 4.256

9.  Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis.

Authors:  Wei-Che Lin; Yu-Chang Lee; Chen-Hsiang Lee; Yeh-Lin Kuo; Yu-Fan Cheng; Chun-Chung Lui; Tien-Tsai Cheng
Journal:  Eur Spine J       Date:  2008-01-18       Impact factor: 3.134

Review 10.  [Kyphoplasty and vertebroplasty for the management of osteoporotic vertebral compression fractures: a systematic review].

Authors:  R Felder-Puig; B Piso; B Guba; G Gartlehner
Journal:  Orthopade       Date:  2009-07       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.