Literature DB >> 16565008

Simulating the straylight effects of cataracts.

Gerard C de Wit1, Luuk Franssen, Joris E Coppens, Thomas J T P van den Berg.   

Abstract

PURPOSE: To study the additional straylight falling on the retina (retinal straylight) caused by cataract and find commercially available filters to simulate the cataract straylight effects.
SETTING: Research laboratory.
METHODS: The retinal straylight addition of cataract was derived from straylight parameter data in the literature. The scattering characteristics of cataract-simulating filters were measured using a scatterometer.
RESULTS: The straylight addition due to cataract follows a power law as a function of angle with power of -2.12 and straylight parameter log values of up to 1.6 for relatively mild cataract cases. Of the commercial filters that were tested, the Tiffen Black Pro Mist (BPM) filters resembled the straylight characteristics of cataracts fairly well. The filters had a limited effect on visual acuity and contrast sensitivity, which was also found for early cataracts. The BPM 2 followed a power law as a function of angle with power of approximately -2.21 and straylight log values of 1.12.
CONCLUSIONS: The BPM 2 filter is a good early-cataract-simulating filter. Stacking such filters is a good way to increase the cataract density. A drawback is that the BPM 2 filter has a transmission of 66% so stacking filters reduces the overall transmission significantly.

Entities:  

Mesh:

Year:  2006        PMID: 16565008     DOI: 10.1016/j.jcrs.2006.01.048

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  25 in total

1.  Effects of yellow filters on visual acuity, contrast sensitivity and reading under conditions of forward light scatter.

Authors:  Frank Eperjesi; Lillian Evangelica Agelis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-08-25       Impact factor: 3.117

2.  Method for in vitro assessment of straylight from intraocular lenses.

Authors:  Grzegorz Łabuz; Fernando Vargas-Martín; Thomas J T P van den Berg; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2015-10-19       Impact factor: 3.732

3.  Retinal straylight and light distortion phenomena in normal and post-LASIK eyes.

Authors:  Alejandro Cerviño; Cesar Villa-Collar; Jose Manuel Gonzalez-Meijome; Teresa Ferrer-Blasco; Santiago García-Lázaro
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-01-18       Impact factor: 3.117

4.  Performance of a differential contrast sensitivity method to measure intraocular scattering.

Authors:  Alexandros Pennos; Harilaos Ginis; Augusto Arias; Dimitrios Christaras; Pablo Artal
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

5.  Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses.

Authors:  Grzegorz Łabuz; Eleni Papadatou; Fernando Vargas-Martín; Norberto López-Gil; Nicolaas J Reus; Thomas J T P van den Berg
Journal:  Biomed Opt Express       Date:  2017-02-27       Impact factor: 3.732

6.  Quantifying intraocular scatter with near diffraction-limited double-pass point spread function.

Authors:  Junlei Zhao; Fei Xiao; Jian Kang; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

7.  System based on the contrast of Purkinje images to measure corneal and lens scattering.

Authors:  Pau Santos; Juan A Martínez-Roda; Juan C Ondategui; Fernando Díaz-Doutón; Jorge A Ortiz Cazal; Meritxell Vilaseca
Journal:  Biomed Opt Express       Date:  2018-09-18       Impact factor: 3.732

8.  Use of diffusing filters for artificially reducing visual acuity when testing equipment and procedures.

Authors:  Sven P Heinrich; Isabell Strübin
Journal:  Doc Ophthalmol       Date:  2019-09-05       Impact factor: 2.379

9.  A modified Hartmann-Shack aberrometer for measuring stray light in the anterior segment of the human eye.

Authors:  Stefan Schramm; Bernd-Ulrich Seifert; Patrick Schikowski; Jürgen Prehl; Kathleen S Kunert; Marcus Blum; André Kaeding; Jens Haueisen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-06-29       Impact factor: 3.117

10.  Intraocular scattering compensation in retinal imaging.

Authors:  Dimitrios Christaras; Harilaos Ginis; Alexandros Pennos; Pablo Artal
Journal:  Biomed Opt Express       Date:  2016-09-13       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.