Literature DB >> 16565001

Pupil measurement using the Colvard pupillometer and a standard pupil card with a cobalt blue filter penlight.

Elyse L Chaglasian1, Sabah Akbar, Louis E Probst.   

Abstract

PURPOSE: To compare scotopic pupil measurements obtained with a Colvard pupillometer with measurements taken with a printed pupil gauge and penlight with a cobalt blue filter attachment in mesopic and scotopic luminance.
SETTING: The Illinois Eye Institute, Chicago, Illinois, USA.
METHODS: Pupil measurements were taken of both eyes of 38 patients (76 eyes). Any subject presenting with anterior segment disease, fixed or dilated pupils, iris abnormalities, or a history of eye disease or eye trauma was excluded. At a mesopic luminance of 2.11 foot-candles, pupil measurements were taken with a Bernell pupil card and penlight with a cobalt blue filter attachment. At a scotopic luminance of less than 2.00 foot-candles, pupil measurements were taken with the Bernell card system and the Colvard pupillometer.
RESULTS: In mesopic luminance, the mean pupil diameter was 5.17 mm (range 3.0 to 7.5 mm) with the Bernell card method. The mean difference between the Colvard in scotopic luminance and the Bernell card system in mesopic luminance was -0.04 mm (P = .0831). In scotopic luminance, the mean pupil diameter was 6.32 mm (range 4.0 to 8.0 mm) with the Bernell card method and 5.13 mm (range 3.0 to 7.5 mm) with the Colvard pupillometer, with a mean difference of -1.18 mm (P<.0001). The limits of agreement between the mesopic Bernell card system and the Colvard pupillometer were small (-0.32 to 0.24), whereas the limits of agreement between the scotopic measurements of both techniques were large (-2.18 to -0.18).
CONCLUSIONS: Under both illuminance conditions, the Bernell card system with the cobalt filter measured a larger pupil size than the Colvard pupillometer. The measurement differences between the techniques were most pronounced at the lower illumination. The limits of agreement were larger under the lower illumination, indicating more variation between techniques. This study suggests that the Bernell card system with cobalt illumination provides a generous measurement of the pupil size compared with the Colvard pupillometer, which makes it an appropriate and cost-effective screening tool for refractive surgery evaluation.

Entities:  

Mesh:

Year:  2006        PMID: 16565001     DOI: 10.1016/j.jcrs.2005.08.061

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Can we measure mesopic pupil size with the cobalt blue light slit-lamp biomicroscopy method?

Authors:  Miguel J Maldonado; Alberto López-Miguel; David P Piñero; José R Juberías; Juan C Nieto; Jorge L Alió
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-01-08       Impact factor: 3.117

2.  Comparison of visual outcomes, spectacles dependence and patient satisfaction of multifocal and accommodative intraocular lenses: innovative perspectives for maximal refractive-oriented cataract surgery.

Authors:  Raffaele Nuzzi; Federico Tridico
Journal:  BMC Ophthalmol       Date:  2017-02-14       Impact factor: 2.209

3.  Analysis of various factors affecting pupil size in patients with glaucoma.

Authors:  Ji Woong Park; Bong Hui Kang; Ji Won Kwon; Kyong Jin Cho
Journal:  BMC Ophthalmol       Date:  2017-09-16       Impact factor: 2.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.