Literature DB >> 16557097

Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta.

Karen May-Newman1, Brian Hillen, Walter Dembitsky.   

Abstract

Computational fluid dynamics (CFD) models were developed to investigate the altered fluid dynamics of the native aorta in patients with a left ventricular assist device (LVAD). The objective of this study was to simulate the effect of LVAD aortic outflow conduit location on the 3-D flow in the native aorta over a range of boundary conditions. The fluid mechanics of three different surgical geometries [(P), proximal, (D), distal and (IP), in-plane] were studied and the implications for short- and long-term medical consequences explored by evaluating the flow fields, wall shear, and hemolysis. The greatest disruptions in the normal aortic flow pattern occurred with series flow conditions, when flow through the aortic valve was minimal. Under series conditions, circulation in the proximal aorta is retrograde, originating from the LVAD outflow conduit. The (P) geometry provided the most blood washout of the proximal aorta, with a larger region of slow-moving flow observed in the (D) and (IP) models. Wall shear stress was reduced for the (IP) geometry, which lacks the direct flow impingement present in the (P) and (D) models. Clinically, the (D) and (IP) geometries require less traumatic surgeries and probably are better tolerated by the patient. In this situation, the (IP) geometry suggests improvement in both increased flow to the proximal aorta and decreased shear stress compared with (D). However, the (D) and (IP) configurations are not recommended for patients with low or no flow from the heart because of the lack of blood washout near the aortic valve and therefore possible thrombus formation in that area.

Entities:  

Mesh:

Year:  2006        PMID: 16557097     DOI: 10.1097/01.mat.0000201961.97981.e9

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  18 in total

Review 1.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

2.  Simulation of the fluid dynamics in artificial aortic roots: comparison of two different types of prostheses.

Authors:  Christoph L Bara; Janko F Verhey
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

Review 3.  Impact of adverse events on ventricular assist device outcomes.

Authors:  Aleksandar Adzic; Snehal R Patel; Simon Maybaum
Journal:  Curr Heart Fail Rep       Date:  2013-03

4.  Impact of LVAD Implantation Site on Ventricular Blood Stagnation.

Authors:  Anthony R Prisco; Alberto Aliseda; Jennifer A Beckman; Nahush A Mokadam; Claudius Mahr; Guilherme J M Garcia
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

5.  The development of aortic insufficiency in left ventricular assist device-supported patients.

Authors:  Jennifer Cowger; Francis D Pagani; Jonathan W Haft; Matthew A Romano; Keith D Aaronson; Theodore J Kolias
Journal:  Circ Heart Fail       Date:  2010-08-25       Impact factor: 8.790

6.  The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Daichi Akiyama; Hirohito Sumikura; Toshihide Mizuno; Tomonori Tsukiya; Yoshiaki Takewa; Kenji Yamazaki; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2018-07-23       Impact factor: 1.731

7.  Change in myocardial oxygen consumption employing continuous-flow LVAD with cardiac beat synchronizing system, in acute ischemic heart failure models.

Authors:  Akihide Umeki; Takashi Nishimura; Yoshiaki Takewa; Masahiko Ando; Mamoru Arakawa; Yuichiro Kishimoto; Tomonori Tsukiya; Toshihide Mizuno; Shunei Kyo; Minoru Ono; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-17       Impact factor: 1.731

8.  Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support.

Authors:  Kei Iizuka; Tomohiro Nishinaka; Yuki Ichihara; Takuma Miyamoto; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2017-11-21       Impact factor: 1.731

9.  Continuous and Pulsatile Pediatric Ventricular Assist Device Hemodynamics with a Viscoelastic Blood Model.

Authors:  Bryan C Good; Steven Deutsch; Keefe B Manning
Journal:  Cardiovasc Eng Technol       Date:  2015-12-07       Impact factor: 2.495

10.  Comparative Study of Continuous and Pulsatile Left Ventricular Assist Devices on Hemodynamics of a Pediatric End-to-Side Anastomotic Graft.

Authors:  Ning Yang; Steven Deutsch; Eric G Paterson; Keefe B Manning
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

View more