Literature DB >> 16551921

Time accuracy of a radio frequency identification patient tracking system for recording operating room timestamps.

Riitta A Marjamaa1, Paulus M Torkki, Markus I Torkki, Olli A Kirvelä.   

Abstract

A patient tracking system is a promising tool for managing patient flow and improving efficiency in the operating room. Wireless location systems, using infrared or radio frequency transmitters, can automatically timestamp key events, thereby decreasing the need for manual data input. In this study, we measured the accuracy and precision of automatically documented timestamps compared with manual recording. Each patient scheduled for urgent surgery was given an active radio frequency/infrared transmitter. The prototype software tracked the patient throughout the perioperative process, automatically documenting the timestamps. Both automatic and traditional data entry were compared with the reference data. The absolute value of median error was 64% smaller (P < 0.01), and the average quartile deviation of error was 69% smaller in automatic documentation. The average delay between an activity and the documentation was 80 seconds in automatic documentation and 735 seconds in manual documentation. Both the accuracy and the precision were better in automatic documentation and the data were immediately available. Automatic documentation with the Indoor Positioning System can help in managing patient flow and in increasing transparency with faster availability and better accuracy of data.

Entities:  

Mesh:

Year:  2006        PMID: 16551921     DOI: 10.1213/01.ane.0000196527.96964.72

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  9 in total

1.  Fuzzy logic-based approach to detecting a passive RFID tag in an outpatient clinic.

Authors:  Daiki Min; Yuehwern Yih
Journal:  J Med Syst       Date:  2009-10-10       Impact factor: 4.460

2.  Accuracy of staff-initiated emergency department tracking system timestamps in identifying actual event times.

Authors:  Bradley D Gordon; Thomas J Flottemesch; Brent R Asplin
Journal:  Ann Emerg Med       Date:  2008-03-07       Impact factor: 5.721

3.  Accuracy of patient's turnover time prediction using RFID technology in an academic ambulatory surgery center.

Authors:  Florence Marchand-Maillet; Claire Debes; Fanny Garnier; Nicolas Dufeu; Didier Sciard; Marc Beaussier
Journal:  J Med Syst       Date:  2015-01-31       Impact factor: 4.460

4.  Radio frequency identification (RFID) in health care: privacy and security concerns limiting adoption.

Authors:  Benjamin P Rosenbaum
Journal:  J Med Syst       Date:  2014-02-28       Impact factor: 4.460

Review 5.  Time motion studies in healthcare: what are we talking about?

Authors:  Marcelo Lopetegui; Po-Yin Yen; Albert Lai; Joseph Jeffries; Peter Embi; Philip Payne
Journal:  J Biomed Inform       Date:  2014-03-07       Impact factor: 6.317

6.  Safety and reliability of Radio Frequency Identification Devices in Magnetic Resonance Imaging and Computed Tomography.

Authors:  Thomas Steffen; Roger Luechinger; Simon Wildermuth; Christian Kern; Christian Fretz; Jochen Lange; Franc H Hetzer
Journal:  Patient Saf Surg       Date:  2010-02-02

7.  [Time delay in beginning first OR positions in the morning].

Authors:  J Unger; M Schuster; K Bauer; H Krieg; R Müller; C Spies
Journal:  Anaesthesist       Date:  2009-03       Impact factor: 1.041

8.  A comparison of commercial and custom-made electronic tracking systems to measure patient flow through an ambulatory clinic.

Authors:  Sharif Vakili; Ravi Pandit; Eric L Singman; Jeffrey Appelbaum; Michael V Boland
Journal:  Int J Health Geogr       Date:  2015-10-29       Impact factor: 3.918

9.  The impact of Joint Commission International accreditation on time periods in the operating room: A retrospective observational study.

Authors:  Takenori Inomata; Ju Mizuno; Masao Iwagami; Shiori Kawasaki; Akie Shimada; Eiichi Inada; Tina Shiang; Atsushi Amano
Journal:  PLoS One       Date:  2018-09-21       Impact factor: 3.240