Literature DB >> 16548089

Validity and reproducibility of hand-held dynamometry in children aged 4-11 years.

Willeke A van den Beld1, Gitty A C van der Sanden, Rob C A Sengers, André L M Verbeek, Fons J M Gabreëls.   

Abstract

OBJECTIVE: To evaluate validity and reproducibility of hand-held dynamometry in 11 different muscle groups in children. DESIGN AND PATIENTS: Maximum isometric muscle strength was measured with a calibrated hand-held dynamometer in 61 patients aged 4-11 years who had been referred to our specialist centre in the past 3 years because of suspected myopathy. All the patients had had muscle biopsy.
METHODS: Validity was assessed by the power to discriminate between patients with and without myopathy, using logistic regression analysis and receiver operating characteristic analysis and sensitivity and specificity at a specifically chosen cut-off point. Reproducibility was evaluated by test-retest reliability in a stratified random sample of 40 patients who returned for re-measurements, using the intraclass correlation coefficient and the standard error of measurement.
RESULTS: In the patients, areas under the receiver operating characteristic curve ranged from 0.66 to 0.88. At a specifically chosen cut-off point, sensitivity varied from 73% to 87%, while specificity varied from 54% to 80%. Intraclass correlation coefficients ranged from 0.73 to 0.91. The standard error of measurement ranged from 3.3 N to 12.2 N.
CONCLUSION: Performance of hand-held dynamometry varied widely in the 11 muscle groups. Highest performance was observed in the elbow flexors. Test-retest reliability of the mean value of 2 efforts was generally higher than the maximum value.

Entities:  

Mesh:

Year:  2006        PMID: 16548089     DOI: 10.1080/16501970510044043

Source DB:  PubMed          Journal:  J Rehabil Med        ISSN: 1650-1977            Impact factor:   2.912


  12 in total

1.  Physical Rehabilitation Practices for Children and Adolescents with Cancer in Canada.

Authors:  Paula A Ospina; Lesley Wiart; David D Eisenstat; Margaret L McNeely
Journal:  Physiother Can       Date:  2020       Impact factor: 1.037

2.  Isometric strength of upper limb muscles in youth using hand-held and hand-grip dynamometry.

Authors:  Guillermo Mendez-Rebolledo; Arturo Ruiz-Gutierrez; Sebastian Salas-Villar; Eduardo Guzman-Muñoz; Sergio Sazo-Rodriguez; Eric Urbina-Santibáñez
Journal:  J Exerc Rehabil       Date:  2022-06-27

3.  Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

Authors:  Kevin McQuade; Robert Price; Nelson Liu; Marcia A Ciol
Journal:  J Nov Physiother       Date:  2012-08-30

4.  Maternal antenatal vitamin D status and offspring muscle development: findings from the Southampton Women's Survey.

Authors:  Nicholas C Harvey; Rebecca J Moon; Avan Aihie Sayer; Georgia Ntani; Justin H Davies; M Kassim Javaid; Sian M Robinson; Keith M Godfrey; Hazel M Inskip; Cyrus Cooper
Journal:  J Clin Endocrinol Metab       Date:  2013-12-20       Impact factor: 5.958

5.  A systematic review of dynamometry and its role in hand trauma assessment.

Authors:  P Mafi; R Mafi; S Hindocha; M Griffin; W Khan
Journal:  Open Orthop J       Date:  2012-02-23

6.  Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents.

Authors:  Luc J Hébert; Désirée B Maltais; Céline Lepage; Joanne Saulnier; Mélanie Crête
Journal:  Pediatr Phys Ther       Date:  2015       Impact factor: 3.049

7.  Stature is an essential predictor of muscle strength in children.

Authors:  Jean-Yves Hogrel; Valérie Decostre; Corinne Alberti; Aurélie Canal; Gwenn Ollivier; Emilie Josserand; Ilham Taouil; Dominique Simon
Journal:  BMC Musculoskelet Disord       Date:  2012-09-18       Impact factor: 2.362

8.  A comparison of cyst wall curettage and en bloc excision in the treatment of aneurysmal bone cysts.

Authors:  Pawel Flont; Marta Kolacinska-Flont; Kryspin Niedzielski
Journal:  World J Surg Oncol       Date:  2013-05-23       Impact factor: 2.754

9.  Intra- and inter-rater reliability of isometric shoulder extensor and internal rotator strength measurements performed using a hand-held dynamometer.

Authors:  Takenori Awatani; Ikuhiro Morikita; Junji Shinohara; Seigo Mori; Miki Nariai; Yasutaka Tatsumi; Akinori Nagata; Hiroya Koshiba
Journal:  J Phys Ther Sci       Date:  2016-11-29

Review 10.  Clinimetric properties of lower limb neurological impairment tests for children and young people with a neurological condition: A systematic review.

Authors:  Ramona Clark; Melissa Locke; Bridget Hill; Cherie Wells; Andrea Bialocerkowski
Journal:  PLoS One       Date:  2017-07-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.