STATEMENT OF PROBLEM: The fit of a dental restoration depends on quality throughout the entire manufacturing process. There is difficulty in assessing the surface topography of an object with a complex form, such as teeth, since there is no exact reference form.
PURPOSE: The purpose of this study was to determine the repeatability and relative accuracy of 2 dental surface digitization devices. A computer-aided design (CAD) technique was used for evaluation to calculate and present the deviations 3-dimensionally.
MATERIAL AND METHODS: Ten dies of teeth prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). The surfaces were digitized 3 times each with an optical or mechanical digitizer. The number of points in the point clouds from each reading were calculated and used as the CAD reference model (CRM). Alignments were performed by registration software that works by minimizing a distance criterion. In color-difference maps, the distribution of the discrepancies between the surfaces in the CRM and the 3-dimensional surface models was identified and located.
RESULTS: The repeatability of both scanners was within 10 microm, based on SD and absolute mean values. The qualitative evaluation resulted in an even distribution of the deviations in the optical digitizer, whereas the dominating part of the surfaces in the mechanical digitizer showed no deviations. The relative accuracy of the 2 surface digitization devices was within +/- 6 microm, based on median values.
CONCLUSION: The repeatability of the optical digitizer was comparable with the mechanical digitization device, and the relative accuracy was similar.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16543016     DOI: 10.1016/j.prosdent.2006.01.003

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  23 in total

1.  Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles.

Authors:  Raquel C Oyagüe; M Isabel Sánchez-Jorge; Andrés Sánchez Turrión
Journal:  Odontology       Date:  2010-07-23       Impact factor: 2.634

2.  Comparison of Marginal Gap and Microleakage in Copy-Milled and Cad-Milled Zirconia Copings Bonded Using Light Cure and Chemical Cure Resin Bonding Systems.

Authors:  Manoj Shetty; S Rajalakshmi; D Krishna Prasad
Journal:  J Indian Prosthodont Soc       Date:  2014-04-23

3.  In vitro Comparison of the Accuracy (Precision and Trueness) of Seven Dental Scanners.

Authors:  Fariborz Vafaee; Farnaz Firouz; Mahsa Mohajeri; Reza Hashemi; Somayeh Ghorbani Gholiabad
Journal:  J Dent (Shiraz)       Date:  2021-03

4.  White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

Authors:  Jin-Hun Jeon; Kyung-Tak Lee; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

5.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

6.  Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner.

Authors:  Jin-Hun Jeon; Dong-Yeon Kim; Jae-Jun Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

7.  A Novel Approach to Determine the Prevalence of Type of Soft Palate Using Digital Intraoral Impression.

Authors:  Saurabh Chaturvedi; Mohamed Khaled Addas; Abdullah Saad Ali Al Humaidi; Abdulrazaq Mohammed Al Qahtani; Mubarak Daghash Al Qahtani
Journal:  Int J Dent       Date:  2017-08-29

8.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16

9.  Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.

Authors:  M Vojdani; K Torabi; E Farjood; Aar Khaledi
Journal:  J Dent (Shiraz)       Date:  2013-09

10.  Reliability and validity of intraoral and extraoral scanners.

Authors:  Helder B Jacob; Graydon D Wyatt; Peter H Buschang
Journal:  Prog Orthod       Date:  2015-10-27       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.