Literature DB >> 16537751

Lack of agreement between thermodilution and fick methods in the measurement of cardiac output.

Peter Baylor1.   

Abstract

A comparison between the thermodilution method and the Fick method of cardiac output measurement in 30 critically ill patients was performed. Although there was good correlation between both methods, there was poor agreement. The Bland and Altman method of assessing agreement between 2 measurements is the preferred method of agreement assessment. The variables possibly responsible for this disagreement are noted.

Entities:  

Mesh:

Year:  2006        PMID: 16537751     DOI: 10.1177/0885066605285234

Source DB:  PubMed          Journal:  J Intensive Care Med        ISSN: 0885-0666            Impact factor:   3.510


  6 in total

1.  Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods.

Authors:  Y H Liu; B P Dhakal; C Keesakul; R M Kacmarek; G D Lewis; Y Jiang
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

2.  Reliability of thermodilution derived cardiac output with different operator characteristics.

Authors:  Scott C McKenzie; Kimble Dunster; Wandy Chan; Martin R Brown; David G Platts; George Javorsky; Chris Anstey; Shaun D Gregory
Journal:  J Clin Monit Comput       Date:  2017-03-09       Impact factor: 2.502

3.  Thermodilution and Fick cardiac outputs differ: impact on pulmonary hypertension evaluation.

Authors:  Wassim H Fares; Sarah K Blanchard; George A Stouffer; Patricia P Chang; Wayne D Rosamond; Hubert James Ford; Robert M Aris
Journal:  Can Respir J       Date:  2012 Jul-Aug       Impact factor: 2.409

4.  Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006.

Authors:  Massimo Antonelli; Mitchell Levy; Peter J D Andrews; Jean Chastre; Leonard D Hudson; Constantine Manthous; G Umberto Meduri; Rui P Moreno; Christian Putensen; Thomas Stewart; Antoni Torres
Journal:  Intensive Care Med       Date:  2007-04       Impact factor: 17.440

5.  Reliability of cardiac output calculation by the fick principle and central venous oxygen saturation in emergency conditions.

Authors:  Avi A Weinbroum; Philippe Biderman; Dror Soffer; Joseph M Klausner; Oded Szold
Journal:  J Clin Monit Comput       Date:  2008-10-23       Impact factor: 2.502

6.  Invasive and noninvasive cardiovascular monitoring options for cardiac surgery.

Authors:  Dominic P Recco; Nathalie Roy; Alexander J Gregory; Kevin W Lobdell
Journal:  JTCVS Open       Date:  2022-04-11
  6 in total