In this work we present a method of calculating dose in deforming anatomy where the position and shape of each dose voxel is tracked as the anatomy changes. The EGSnrc/DOSXYZnrc Monte Carlo code was modified to calculate dose in voxels that are deformed according to deformation vectors obtained from a nonlinear image registration algorithm. The defDOSXYZ code was validated by consistency checks and by comparing calculations against DOSXYZnrc calculations. Calculations in deforming phantoms were compared with a dose remapping method employing trilinear interpolation. Dose calculations with the deforming voxels agree with DOSXYZnrc calculations within 1%. In simple deforming rectangular phantoms the trilinear dose remapping method was found to underestimate the dose by up to 29% for a 1.0 cm voxel size within the field, with larger discrepancies in regions of steep dose gradients. The agreement between the two calculation methods improved with smaller voxel size and deformation magnitude. A comparison of dose remapping from Inhale to Exhale in an anatomical breathing phantom demonstrated that dose deformations are underestimated by up to 16% in the penumbra and 8% near the surface with trilinear interpolation.

Mesh:

Year:  2006        PMID: 16532951     DOI: 10.1118/1.2163252

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations.

Authors:  C Yan; G Hugo; F J Salguero; N Saleh-Sayah; E Weiss; W C Sleeman; J V Siebers
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  A mass-conserving 4D XCAT phantom for dose calculation and accumulation.

Authors:  Christopher L Williams; Pankaj Mishra; Joao Seco; Sara St James; Raymond H Mak; Ross I Berbeco; John H Lewis
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping.

Authors:  Francisco J Salguero; Nahla K Saleh-Sayah; Chenyu Yan; Jeffrey V Siebers
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

Review 4.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

5.  On voxel-by-voxel accumulated dose for prostate radiation therapy using deformable image registration.

Authors:  Jialu Yu; Nicholas Hardcastle; Kyoungkeun Jeong; Edward T Bender; Mark A Ritter; Wolfgang A Tomé
Journal:  Technol Cancer Res Treat       Date:  2014-11-11

6.  Direct dose mapping versus energy/mass transfer mapping for 4D dose accumulation: fundamental differences and dosimetric consequences.

Authors:  Haisen S Li; Hualiang Zhong; Jinkoo Kim; Carri Glide-Hurst; Misbah Gulam; Teamour S Nurushev; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2013-12-13       Impact factor: 3.609

7.  Adaptive radiotherapy for NSCLC patients: utilizing the principle of energy conservation to evaluate dose mapping operations.

Authors:  Hualiang Zhong; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2017-05-05       Impact factor: 3.609

8.  Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

Authors:  Ross McGurk; Joao Seco; Marco Riboldi; John Wolfgang; Paul Segars; Harald Paganetti
Journal:  Phys Med Biol       Date:  2010-02-16       Impact factor: 3.609

9.  An energy transfer method for 4D Monte Carlo dose calculation.

Authors:  Jeffrey V Siebers; Hualiang Zhong
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

10.  Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry.

Authors:  Juying Zhang; George X Xu; Chengyu Shi; Martin Fuss
Journal:  J Appl Clin Med Phys       Date:  2008-01-21       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.