Literature DB >> 16527232

Detection of narrow angles and established angle closure in Chinese residents of Singapore: potential screening tests.

Winifred P Nolan1, Tin Aung, David Machin, Peng T Khaw, Gordon J Johnson, Steve K L Seah, Paul J Foster.   

Abstract

PURPOSE: To assess the performance of peripheral and central anterior chamber depth (ACD) measurements, and autorefraction, in identifying Chinese people with occludable drainage angles or established primary angle closure.
DESIGN: Population-based cross-sectional analysis.
METHODS: Subjects aged 40 years and older were drawn from a representative sample of Chinese Singaporean residents. Limbal chamber depth (LCD) was estimated and central ACD was measured using optical pachymetry and ultrasound. An autorefraction was taken for all subjects. Angle width and the presence of peripheral anterior synechiae were determined by gonioscopy. Receiver operating characteristic curves were generated to show the performance of these tests in detecting occludable angles.
RESULTS: A total of 1090 subjects were examined. The prevalence of occludable angles was 6.5%. LCD measurement performed best in detecting occludable angles (area under the curve [AUC] 0.904, 95% confidence interval [CI] 0.870, 0.937). Optical pachymetry and ultrasound measurement of ACD performed less well (AUC 0.859 and 0.810, respectively), and autorefraction performed poorly in detecting occludable angles (AUC 0.632). LCD also gave the best performance in detecting primary angle closure (AUC 0.782, 95% CI 0.727, 0.837).
CONCLUSIONS: Limbal LCD estimation outperforms other methods of measuring ACD as a screening tool for the detection of occludable drainage angles in the Chinese population of Singapore.

Entities:  

Mesh:

Year:  2006        PMID: 16527232     DOI: 10.1016/j.ajo.2005.12.008

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  13 in total

1.  The biometric study in different stages of primary angle-closure glaucoma.

Authors:  Y-Y Chen; Y-Y Chen; S-J Sheu; P Chou
Journal:  Eye (Lond)       Date:  2013-06-21       Impact factor: 3.775

2.  Appositional closure identified by ultrasound biomicroscopy in population-based primary angle-closure glaucoma suspects: the Liwan eye study.

Authors:  Xiangbin Kong; Paul J Foster; Qunxiao Huang; Yingfeng Zheng; Wenyong Huang; Xiaoyu Cai; Mingguang He
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-07       Impact factor: 4.799

3.  Five-year incidence of angle closure among glaucoma health examination participants.

Authors:  Kenji Kashiwagi; Tatsuya Chiba; Fumihiko Mabuchi; Toshie Furuya; Shigeo Tsukahara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-25       Impact factor: 3.117

4.  Comparison of slit lamp-adapted optical coherence tomography features of fellow eyes of acute primary angle closure and eyes with open angle glaucoma.

Authors:  Argyrios Tzamalis; Duy-Thoai Pham; Christopher Wirbelauer
Journal:  Jpn J Ophthalmol       Date:  2014-02-06       Impact factor: 2.447

5.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

6.  High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

Authors:  Michael I Seider; Melike Pekmezci; Ying Han; Simi Sandhu; Shiu Y Kwok; Roland Y Lee; Shan C Lin
Journal:  J Glaucoma       Date:  2009 Oct-Nov       Impact factor: 2.503

Review 7.  Prevalence of glaucoma in rural Myanmar: the Meiktila Eye Study.

Authors:  R J Casson; H S Newland; J Muecke; S McGovern; L Abraham; W K Shein; D Selva; T Aung
Journal:  Br J Ophthalmol       Date:  2007-06       Impact factor: 4.638

8.  The prevalence and break down of narrow anterior chamber angle pathology presenting to a general ophthalmology clinic.

Authors:  Nikhil Jain; Rashad Zia
Journal:  Medicine (Baltimore)       Date:  2021-06-18       Impact factor: 1.817

9.  Comparison of anterior segment optical tomography parameters measured using a semi-automatic software to standard clinical instruments.

Authors:  Marcus Ang; Wesley Chong; Huiqi Huang; Wan Ting Tay; Tien Yin Wong; Ming-Guang He; Tin Aung; Jodhbir S Mehta
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

10.  Risk factors for progressive visual field loss in primary angle-closure glaucoma: a retrospective cohort study.

Authors:  Nai-Wen Fan; De-Kuang Hwang; Yu-Chieh Ko; Fan-Chen Tseng; Kuo-Hsuan Hung; Catherine Jui-Ling Liu
Journal:  PLoS One       Date:  2013-07-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.