Literature DB >> 16519892

Direct comparison of capillary electrophoresis and capillary liquid chromatography hyphenated to collision-cell inductively coupled plasma mass spectrometry for the investigation of Cd-, Cu- and Zn-containing metalloproteins.

Maria Montes-Bayon1, Daniel Pröfrock, Alfredo Sanz-Medel, Andreas Prange.   

Abstract

Capillary liquid chromatography (cLC) and capillary electrophoresis (CE) have been critically compared for the separation of metalloproteins when using collision-cell inductively coupled plasma mass spectrometry (ICP-CC-MS) as detection system. For cLC separation, the selected column was a C8 (0.3 mm I.D.) and the separation conditions involved a gradient up to 80% methanol in 10mM ammonium acetate buffer (pH 7.4). The low flow rate used (3 microL min(-1)) permitted the utilization of a high methanol content maintaining the sensitivity along the whole chromatographic run. For this purpose, a new low-flow interface has been developed based on a total consumption nebulizer. Similarly, CE has been studied as separation technique using a 75 microm I.D. fused silica capillary and a running buffer of 20 mM Tris-HNO3 (pH 7.4) and working at 30 kV. Metallothionein (mixture of MT-I and -II) and superoxide dismutase (SOD) have been used as protein models in order to evaluate the separation/detection capabilities using the same injection volumes in both systems (20 nL). For both hybrid systems, separation parameters such as retention factor, numbers of theoretical plates, tailing factor and resolution have been critically compared. Also, the analytical performance characteristics of both hybrid systems have been evaluated and tested by analyzing the Cu-, Zn-species present in red blood cell extracts in order to explore more adequate separation methodology for the analysis of metalloproteins in complex matrices.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16519892     DOI: 10.1016/j.chroma.2006.02.028

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Simple method for identification of metallothionein isoforms in cultured human prostate cells by MALDI-TOF/TOF mass spectrometry.

Authors:  Rongying Wang; Donald A Sens; Amy Albrecht; Scott Garrett; Seema Somji; Mary Ann Sens; Xiaoning Lu
Journal:  Anal Chem       Date:  2007-05-12       Impact factor: 6.986

2.  Assessment of seasonal variation for air pollutant accumulation by Zizyphus tree under washing treatment.

Authors:  Mohamed Abdulraheem Shaheen; Fathy Saad El-Nakhlawy; Fahd Mosallam Almehmadi; Muhammad Zahid Ihsan; Abdulmohsin Rajeh Al-Shareef
Journal:  Environ Monit Assess       Date:  2016-05-11       Impact factor: 2.513

3.  Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples.

Authors:  Mahmoud Chamsaz; Atefe Atarodi; Mohammad Eftekhari; Saeid Asadpour; Mina Adibi
Journal:  J Adv Res       Date:  2012-01-13       Impact factor: 10.479

4.  Cellulose-lanthanum hydroxide nanocomposite as a selective marker for detection of toxic copper.

Authors:  Hadi M Marwani; Mazhar Ullah Lodhi; Sher Bahadar Khan; Abdullah M Asiri
Journal:  Nanoscale Res Lett       Date:  2014-09-03       Impact factor: 4.703

5.  Current literature in mass spectrometry.

Authors: 
Journal:  J Mass Spectrom       Date:  2007-01       Impact factor: 1.982

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.