Literature DB >> 16517177

Cyclic polyamide oligomers extracted from nylon 66 membrane filter disks as a source of contamination in liquid chromatography/mass spectrometry.

John C Tran1, Alan A Doucette.   

Abstract

Background interferences are perhaps an unavoidable part of analytical detection schemes, particularly when analyzing trace level samples or when using detectors with high levels of sensitivity. In liquid chromatography, mobile phase solvents are routinely filtered using membrane filter disks to trap particulates in hopes of minimizing contamination, providing improvements in data output and instrumental operation. In this study, we report that one such filter disk leads to a significant level of contamination in LC and LC/MS experiments. Extractable compounds from nylon membrane filters generate significant background signals in UV absorption chromatograms at 214 nm, and are also detected by electrospray ionization mass spectrometry, with nominal m/z values of 453 and 679. It is shown that rinsing the nylon membranes before their use can reduce, but will not eliminate, the extractable contaminants from the mobile phase. Through MS and tandem MS analysis, we have identified these contaminants as cyclic oligomers of polyamide 66. Based on these results, it is recommended that nylon membrane filters be avoided when conducting trace level analysis, particularly when conducting LC/MS experiments.

Entities:  

Year:  2006        PMID: 16517177     DOI: 10.1016/j.jasms.2006.01.008

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  12 in total

1.  On the nature of the chemical noise in MALDI mass spectra.

Authors:  Andrew N Krutchinsky; Brian T Chait
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

2.  A combined linear ion trap time-of-flight system with improved performance and MS(n) capabilities.

Authors:  B A Collings; J M Campbell; D Mao; D J Douglas
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

3.  Plasticizer contamination from vacuum system O-rings in a quadrupole ion trap mass spectrometer.

Authors:  Kent M Verge; George R Agnes
Journal:  J Am Soc Mass Spectrom       Date:  2002-08       Impact factor: 3.109

4.  Ultrapure water for liquid chromatography-mass spectrometry studies.

Authors:  Cecilia Regnault; Ichiro Kano; Daniel Darbouret; Stéphane Mabic
Journal:  J Chromatogr A       Date:  2004-03-19       Impact factor: 4.759

Review 5.  Ghost peaks in reversed-phase gradient HPLC: a review and update.

Authors:  Stuart Williams
Journal:  J Chromatogr A       Date:  2004-10-15       Impact factor: 4.759

6.  Identification of a new source of interference leached from polypropylene tubes in mass-selective analysis.

Authors:  Yuan-Qing Xia; Shefali Patel; Ray Bakhtiar; Ronald B Franklin; George A Doss
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

7.  Anomalous liquid chromatographic results originating from the presence of soap residues and the use of nylon filters.

Authors:  D E Hughes; A M Bramer
Journal:  J Chromatogr       Date:  1987-11-06

8.  Endgroup-based separation and quantitation of polyamide-6,6 by means of critical chromatography.

Authors:  Y Mengerink; R Peters; Sj van der Wal; H A Claessens; C A Cramers
Journal:  J Chromatogr A       Date:  2002-03-08       Impact factor: 4.759

9.  Analysis of linear and cyclic oligomers in polyamide-6 without sample preparation by liquid chromatography using the sandwich injection method. II. Methods of detection and quantification and overall long-term performance.

Authors:  Y Mengerink; R Peters; M Kerkhoff; J Hellenbrand; H Omloo; J Andrien; M Vestjens; S van der Wal
Journal:  J Chromatogr A       Date:  2000-05-05       Impact factor: 4.759

10.  Identification of diethylene glycol monobutyl ether as a source of contamination in an ion trap mass spectrometer.

Authors:  Christopher R Gibson; Cheri M Brown
Journal:  J Am Soc Mass Spectrom       Date:  2003-11       Impact factor: 3.109

View more
  5 in total

1.  Implementing Multi-Enzyme Biocatalytic Systems Using Nanoparticle Scaffolds.

Authors:  Joyce C Breger; Gregory A Ellis; Scott A Walper; Kimihiro Susumu; Igor L Medintz
Journal:  Methods Mol Biol       Date:  2022

2.  Extractable impurities from fluoropolymer-based membrane filters - interference in high-throughput, untargeted analysis.

Authors:  Perng Yang Puah; Dexter Jiunn Herng Lee; Ken Hing Mak; Hui Jun Ang; Hsing-Chang Chen; Pak Yan Moh; Siat Yee Fong; Yee Soon Ling
Journal:  RSC Adv       Date:  2019-10-08       Impact factor: 4.036

3.  Identification of dimethyldioctadecylammonium ion (m/z 550.6) and related species (m/z 522.6, 494.6) as a source of contamination in mass spectrometry.

Authors:  M Lisa Manier; D Shannon Cornett; David L Hachey; Richard M Caprioli
Journal:  J Am Soc Mass Spectrom       Date:  2008-02-08       Impact factor: 3.109

4.  The Synthesis and Structural Characterization of Graft Copolymers Composed of γ-PGA Backbone and Oligoesters Pendant Chains.

Authors:  Iwona Kwiecień; Iza Radecka; Marek Kowalczuk; Katarzyna Jelonek; Arkadiusz Orchel; Grażyna Adamus
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-10       Impact factor: 3.109

5.  Confirmation of pinnatoxins and spirolides in shellfish and passive samplers from Catalonia (Spain) by liquid chromatography coupled with triple quadrupole and high-resolution hybrid tandem mass spectrometry.

Authors:  María García-Altares; Alexis Casanova; Vaishali Bane; Jorge Diogène; Ambrose Furey; Pablo de la Iglesia
Journal:  Mar Drugs       Date:  2014-06-23       Impact factor: 5.118

  5 in total