Literature DB >> 16511788

Comparison of Multistix PRO dipsticks with other biochemical assays for determining urine protein (UP), urine creatinine (UC) and UP:UC ratio in dogs and cats.

Elizabeth G Welles1, Elizabeth M Whatley, Amy S Hall, James C Wright.   

Abstract

BACKGROUND: Urine protein: urine creatinine (UP:UC) ratio determined from the quantitative measurement of protein and creatinine in a single urine sample is the best feasible assessment of clinically significant proteinuria in dogs and cats. A dipstick that measures urine protein, urine creatinine, and UP:UC ratio has been used in human medicine and could have application for veterinary practice.
OBJECTIVE: The objective of this study was to compare the Multistix PRO dipstick (Bayer Corporation, Elkhart, IN, USA) to other biochemical methods for determination of urine protein and creatinine, and UP:UC ratio in canine and feline urine.
METHODS: A complete urinalysis, including sulfosalicylic acid (SSA) precipitation, was performed on urine samples submitted to our laboratory between February and April 2003 from 100 dogs and 49 cats. Urine protein and creatinine concentrations were determined by the Multistix PRO dipstick using a Clinitek 50 analyzer (Bayer) and compared with the results of SSA precipitation and quantitative biochemical analysis. The UP:UC ratios from the dipstick results (calculated by the Clinitek 50 and also manually) were compared with those calculated from quantitative values. Pearson product-moment correlation analysis and diagnostic sensitivity and specificity (using quantitative results as the gold standard) were determined.
RESULTS: For both canine and feline urine, protein and creatinine concentrations determined by the Multistix PRO correlated closely with quantitative concentrations for protein (dogs r = .78, P = .0001; cats r = .87, P = .0001) and creatinine (dogs r = .78, P = .0001; cats r = .76, P = .0001). The Multistix PRO was more sensitive and less specific than SSA precipitation for diagnosing clinically significant proteinuria. UP:UC ratios obtained by manual calculation of dipstick results correlated best with quantitative UP:UC ratios in dogs, and had higher specificity but lower sensitivity for the diagnosis of proteinuria. In cats, UP:UC ratios determined by the dipstick method did not correlate (r = -.24, P = .0974) with quantitative values.
CONCLUSIONS: The Multistix PRO, with manual calculation of UP:UC, may be a good alternative for the diagnosis of clinically significant proteinuria in dogs, but not cats. Dipstick creatinine concentration should be considered as an estimate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16511788     DOI: 10.1111/j.1939-165x.2006.tb00085.x

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  3 in total

1.  Evaluation of the accuracy of urine analyzers in dogs and cats.

Authors:  Keiichiro Mie; Akiyoshi Hayashi; Hidetaka Nishida; Mari Okamoto; Kazuo Yasuda; Mio Nakata; Kazuyuki Fukatsu; Norie Matsunami; Shogo Yamashita; Fumihito Ohashi; Hideo Akiyoshi
Journal:  J Vet Med Sci       Date:  2019-10-11       Impact factor: 1.267

2.  Comparison of three types of analyzers for urine protein-to-creatinine ratios in dogs.

Authors:  Sumin Ji; Yeseul Yang; Yeji Jeong; Sung Hyun Hwang; Myung Chul Kim; Yongbaek Kim
Journal:  J Vet Sci       Date:  2021-01       Impact factor: 1.672

3.  Basal glucosuria in cats.

Authors:  Florian Karl Zeugswetter; Theresa Polsterer; Herbert Krempl; Ilse Schwendenwein
Journal:  J Anim Physiol Anim Nutr (Berl)       Date:  2018-10-29       Impact factor: 2.130

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.