Literature DB >> 16501986

Press fit fixation of cementless cups: how much stability do we need indeed?

A Roth1, T Winzer, K Sander, J O Anders, R-A Venbrocks.   

Abstract

INTRODUCTION: Using screws for a better primary and secondary fixation has been discussed in the literature of the recent years, although the principle of press fit has been explained as the principle of a push-button. The authors wanted to compare their own results in patients using X-rays from the postoperative course to decide if it is really safer to use screws or not.
MATERIALS AND METHODS: Two hundred and twenty one consecutive, not selected patients were treated with total hip arthroplasty using a cementless cup type Duraloc. They were followed up over a time of 5 years for radiological changes of the bony acetabulum around the cup ("acetabular zones" according to De Lee and Charnley). One hundred and ten cups were additionally fixed with one to three screws at the upper part in region C1, 101 cups were implanted without the use of screws.
RESULTS: Periprosthetic changes visible on the radiographs (immediate postoperative gaps, subsequent sclerosis and radiolucent lines) were assessed according to the time of their appearance. A gap in zone C2 was seen more often immediately after operation within the group without screws (17.8% vs. 7.3%) and disappeared within the following 25 months. Within the group with screws significantly more often a gap was found in zone C1 and C3 compared to the group without screws (7.3% vs. 1.9%). In the group with screws a sclerosis of the bone in zone C1 developed in 32.7% mostly within the first 5 months. It was followed by a radiolucent line in zone C3 in 28.2% mainly within 5-25 months postoperatively and in zone C1 in 20.9% within 16 months. Significantly less seldom were these phenomena seen at the cups without screw fixation. There was no correlation between lateral or medial positioning and deviations from the ideal inclination to the bony changes around the cups. No signs of loosening occurred in either group.
CONCLUSION: Less radiological changes around the cup if no screws were used and no disadvantages within this group led to the conclusion that an additional screw fixation in principle is not necessary in press-fit cups.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16501986     DOI: 10.1007/s00402-005-0001-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  17 in total

1.  Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model.

Authors:  David Markel; Judd Day; Ryan Siskey; Imants Liepins; Steven Kurtz; Kevin Ong
Journal:  Int Orthop       Date:  2010-07-13       Impact factor: 3.075

2.  Press-fit cementless acetabular fixation with and without screws.

Authors:  Sheng-Hui Ni; Lei Guo; Tian-Long Jiang; Jie Zhao; Yan-Gang Zhao
Journal:  Int Orthop       Date:  2013-08-28       Impact factor: 3.075

3.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

4.  Acetabular component thickness does not affect mid-term clinical results in hip resurfacing.

Authors:  Mariam Al-Hamad; Michel J Le Duff; Karren M Takamura; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2014-01-22       Impact factor: 4.176

5.  Letter to the Editor Regarding Sukhsathein et al.: "Cup Alignment Change After Screw Fixation in Total Hip Arthroplasty".

Authors:  Mandeep S Dhillon; Himanshu Bhayana; Sandeep Patel
Journal:  Indian J Orthop       Date:  2020-07-09       Impact factor: 1.251

6.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10

9.  Cementless total hip replacement: past, present, and future.

Authors:  Harumoto Yamada; Yasuo Yoshihara; Osamu Henmi; Mitsuhiro Morita; Yuichiro Shiromoto; Tomoki Kawano; Arihiko Kanaji; Kennichi Ando; Masato Nakagawa; Naoto Kosaki; Eiichi Fukaya
Journal:  J Orthop Sci       Date:  2009-04-01       Impact factor: 1.601

10.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.