Literature DB >> 16500110

Aortic prosthetic ring annuloplasty: a useful adjunct to a standardized aortic valve-sparing procedure?

Emmanuel Lansac1, Isabelle Di Centa, Nicolas Bonnet, Pascal Leprince, Akthar Rama, Christophe Acar, Alain Pavie, Iradj Gandjbakhch.   

Abstract

OBJECTIVE: Dilation of aortic annulus, sinuses of Valsalva, and sinotubular junction (STJ) diameters are the characteristic lesions of aortic root aneurysm. The remodeling technique reduces STJ diameter and creates three neosinuses of Valsalva. Alternatively, the reimplantation technique reduces both annulus and STJ diameters to the detriment of aortic root dynamics. Although the remodeling technique is recognized as the most physiological valve-sparing procedure, aortic annulus dilation may jeopardize its results. A standardized approach that combines an external subvalvular aortic prosthetic ring annuloplasty with the remodeling technique is suggested.
METHODS: Eighty-three patients underwent an elective aortic root remodeling procedure, either isolated (group 1, n=34) or combined with an external subvalvular aortic prosthetic ring annuloplasty (group 2, n=49). Preoperative aortic regurgitation was 1.59+/-1.1 (group 1) and 1.97+/-1.3 (group 2) (NS). The aortic annulus was more dilated in group 2 than in group 1 (27+/-2.77 mm vs 26.4+/-2.3 mm, p<0.01). Residual aortic regurgitation > or =grade II was the conversion criteria for aortic valve replacement.
RESULTS: Operative mortality was 3.6% (n=3). Intraoperative conversion for valve replacement was 32.7% in group 1 (n=11) versus 4.2% in group 2 (n=2) (p<0.001). In group 1, preoperative annulus diameter was larger for converted than for valve-spared patients (27.6+/-1.7 mm vs 25.2+/-1.5 mm, p<0.02). In group 2, implanted aortic ring significantly reduced annulus diameter (20.6+/-1.8 mm) without significant aortic valve gradient (8.3+/-3 mmHg). Follow-up was 17.2+/-13.4 months (group 1) and 10.41+/-7.95 months (group 2). Reoperation for recurrent aortic regurgitation was 13% in group 1 (n=3) versus 4.2% in group 2 (n=2). Echocardiographic follow-up found residual aortic regurgitation < or =grade I in 17 patients in group 1 (90%) versus 43 patients in group 2 (95.5%) and of grade II in two patients in group 1 (10%) and two patients in group 2 (4.5%).
CONCLUSION: The addition of external aortic prosthetic ring annuloplasty improves the remodeling technique's operative reproducibility and short-term results. Therefore, its use as a systematical adjunct to the remodeling procedure is suggested. However, further long-term evaluation comparing this valve-sparing procedure to composite graft replacement should define the best surgical strategy for aortic root aneurysm.

Entities:  

Mesh:

Year:  2006        PMID: 16500110     DOI: 10.1016/j.ejcts.2005.12.055

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  10 in total

Review 1.  Annular management during aortic valve repair: a systematic review.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-11-25

2.  Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

Authors:  Emmanuel Lansac; Isabelle Di Centa; Jan Vojacek; Jan Nijs; Jaroslav Hlubocky; Gianclaudio Mecozzi; Mathieu Debauchez
Journal:  Ann Cardiothorac Surg       Date:  2013-01

3.  Sparing aortic valve techniques.

Authors:  Rubén Álvarez-Cabo
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

4.  Aortic annulus and the importance of annuloplasty.

Authors:  Pouya Youssefi; Emmanuel Lansac
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-10-07

5.  Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement.

Authors:  Reza Tavakoli; Guillaume Lebreton; Max Gassmann; Peiman Jamshidi; Pascal Leprince
Journal:  J Vis Exp       Date:  2017-12-11       Impact factor: 1.355

6.  Calibrated cusp sizers to facilitate aortic valve repair: development and clinical application.

Authors:  Mohammad Bashar Izzat
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-11-29

Review 7.  Aortic valve repair: indications and outcomes.

Authors:  Munir Boodhwani; Gebrine El Khoury
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

8.  Systematic review of aortic valve preservation and repair.

Authors:  Richard Saczkowski; Tarek Malas; Laurent de Kerchove; Gebrine El Khoury; Munir Boodhwani
Journal:  Ann Cardiothorac Surg       Date:  2013-01

9.  Comparison of Dacron ring and suture annuloplasty for aortic valve repair-a porcine study.

Authors:  Leila Louise Benhassen; Diana Mathilde Ropcke; Mona Sharghbin; Troels Lading; Jens Kæstel Skov; Marcell Juan Tjørnild; Karen Bagger Poulsen; Tommy Bechsgaard; Søren Nielsen Skov; Sten Lyager Nielsen; John Michael Hasenkam
Journal:  Ann Cardiothorac Surg       Date:  2019-05

10.  Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair.

Authors:  Leila Louise Benhassen; Jacob Hesselby Hedensted; Mona Sharghbin; Søren Nielsen Skov; Lisa Carlson Hanse; Marcell Juan Tjørnild; Tommy Bechsgaard; Diana Mathilde Ropcke; Sten Lyager Nielsen; John Michael Hasenkam
Journal:  Eur J Cardiothorac Surg       Date:  2020-06-01       Impact factor: 4.191

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.