Literature DB >> 16498942

Split renal function in patients with suspected renal artery stenosis: a comparison between gamma camera renography and two methods of measurement with computed tomography.

H Björkman1, H Eklöf, J Wadström, L G Andersson, R Nyman, A Magnusson.   

Abstract

PURPOSE: To validate a method for calculating split renal function from computed tomography (CT) compared with gamma camera renography, and to test a new method for the measurement based on a volume-rendering technique.
MATERIAL AND METHODS: Thirty-eight patients, aged 65.7 +/- 11.6 (range 37.8-82.1) years, who had undergone both CT angiography and gamma camera renography for a suspected renal artery stenosis were included in this study. Split renal function was calculated from the CT examinations by measuring area and mean attenuation in the image slices of the kidneys, and also by measuring volume and mean attenuation from a 3D reconstruction of the kidneys. Gamma camera renography with 99mTc-MAG3 with or without captopril enhancement was used as a reference.
RESULTS: The 2D CT method had good correlation with renography (r=0.93). Mean difference was 4.7 +/- 3.6 (0-12) percentage points per kidney. There was also excellent correlation between the two CT methods (r=1.00).
CONCLUSION: CT is equivalent to renography in determining split renal function, and the measurement from the CT examination can be made more quickly and equally accurately with a 3D technique.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16498942     DOI: 10.1080/02841850500406787

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors.

Authors:  Matthew K Knox; Michael D Rivers-Bowerman; Harry P Bardgett; Nigel C Cowan
Journal:  Eur Radiol       Date:  2010-06-27       Impact factor: 5.315

2.  Determination of split renal function by 3D reconstruction of CT angiograms: a comparison with gamma camera renography.

Authors:  Adam L Summerlin; Mark E Lockhart; Andrew M Strang; Peter N Kolettis; Naomi S Fineberg; J Kevin Smith
Journal:  AJR Am J Roentgenol       Date:  2008-11       Impact factor: 3.959

3.  Can Split Renal Volume Assessment by Computed Tomography Replace Nuclear Split Renal Function in Living Kidney Donor Evaluations? A Systematic Review and Meta-Analysis.

Authors:  Steven Habbous; Carlos Garcia-Ochoa; Gary Brahm; Chris Nguan; Amit X Garg
Journal:  Can J Kidney Health Dis       Date:  2019-09-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.