Literature DB >> 16495372

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study.

Sunil Hirani1, Martyn Sherriff.   

Abstract

Little is known about the performance of Transbond Plus Self-Etching Primer (TPSEP), especially when used with Adhesive Precoated Brackets (APC 1 and APC 2). The aim of this study was to compare the shear bond and rebond strengths and failure sites of APC 1 and APC 2 with a non-coated bracket system [Victory Series (V)] using Transbond XT light-cured adhesive and TPSEP or 37 percent phosphoric acid as the conditioner. The results demonstrated that on dry testing of 120 brackets when applying an occluso-gingival load to produce a shear force at the bracket-tooth interface, there was no statistically significant difference in the shear bond strength (SBS) of APC 1 (68.4 N), APC 2 (74.9 N), and V brackets (75.4 N, control group). There was also no significant difference in bond failure sites of the APC 1 and APC 2 when compared with the non-coated bracket system using Transbond XT light-cured adhesive and TPSEP, with bond failure for all groups occurring mainly at the adhesive-enamel interface. There was a significant difference in the SBS of the V brackets when using TPSEP and 37 percent phosphoric acid as the conditioners. The latter was lower (60.6 N) and the bond failure site changed from the enamel-adhesive interface to the bracket-adhesive interface. The shear rebond strengths of all bracket types were statistically significantly lower (P < 0.05) than their initial SBS (APC 1, APC 2, and V: 35.9, 36.7, and 34.1 N, respectively) and the locus of bond failure altered from the adhesive-enamel interface to the bracket-adhesive interface. A clinical trial using TPSEP as a conditioner would be useful as the time taken to remove the adhesive from the enamel surface may be reduced following debond.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16495372     DOI: 10.1093/ejo/cji107

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  2 in total

1.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

Review 2.  The Indirect Bonding Technique in Orthodontics-A Narrative Literature Review.

Authors:  Agnieszka Nawrocka; Monika Lukomska-Szymanska
Journal:  Materials (Basel)       Date:  2020-02-22       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.