Literature DB >> 16495124

EPR investigation of the gamma radiation response of different types of glasses.

Veselka Gancheva1, Nicola D Yordanov, Yordanka Karakirova.   

Abstract

Several types of laboratory glasses such as: "Jena", "Rasotherm", "Thüring" as well as window and windscreen glasses were studied by the method of EPR spectroscopy as possible emergency radiation dosimeters for gamma-ray irradiation. The most appropriate values of modulation amplitude and microwave power were found to obtain best sensitivity for the measured signals. Dose measurements have shown a linear dependence between the EPR signal intensity of radiation created defects in glasses and applied dose in the dose range 50-500 Gy. "Thüring" glass was found to be the most sensitive sample to radiation. The magnitude of window glass absorbed dose was evaluated as the difference between the intensity of its EPR signal recorded after irradiation and the background signal, obtained after thermal relaxation of the former.

Mesh:

Year:  2006        PMID: 16495124     DOI: 10.1016/j.saa.2005.10.019

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  4 in total

Review 1.  Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry.

Authors:  Céline M Desmet; Philippe Levêque; Bernard Gallez
Journal:  Radiat Prot Dosimetry       Date:  2016-07-29       Impact factor: 0.972

2.  EPR dosimetry intercomparison using smart phone touch screen glass.

Authors:  Paola Fattibene; Francois Trompier; Albrecht Wieser; Maria Brai; Bartlomej Ciesielski; Cinzia De Angelis; Sara Della Monaca; Tristan Garcia; H Gustafsson; Eli Olag Hole; M Juniewicz; K Krefft; Anna Longo; Philippe Leveque; Eva Lund; Maurizio Marrale; Barbara Michalec; Gabriela Mierzwińska; J L Rao; Alexander A Romanyukha; Hasan Tuner
Journal:  Radiat Environ Biophys       Date:  2014-03-27       Impact factor: 1.925

3.  Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites.

Authors:  Céline M Desmet; Andrej Djurkin; Ana Maria Dos Santos-Goncalvez; Ruhong Dong; Maciej M Kmiec; Kyo Kobayashi; Kevin Rychert; Sébastien Beun; Julian G Leprince; Gaëtane Leloup; Philippe Levêque; Bernard Gallez
Journal:  PLoS One       Date:  2015-06-30       Impact factor: 3.240

4.  Time evolution of radiation-induced EPR signals in different types of mobile phone screen glasses.

Authors:  Małgorzata Juniewicz; Bartłomiej Ciesielski; Agnieszka Marciniak; Anita Prawdzik-Dampc
Journal:  Radiat Environ Biophys       Date:  2019-07-01       Impact factor: 1.925

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.