Literature DB >> 16494095

Comparison of clinical outcomes using a nickel titanium rotary or stainless steel hand file instrumentation technique.

Donald J Kleier1, Robert Averbach.   

Abstract

The purpose of this study was to evaluate the concept that novice clinicians could perform clinical endodontics better and more efficiently if the stainless steel hand file technique is replaced with a nickel titanium rotary file technique. In phase 1 of the study, every endodontic case performed by 2 groups was evaluated for total treatment time. In phase 2, the mesial roots of mandibular molars were evaluated for radiographic quality of completed obturation. The authors found that when the rotary file technique was substituted for the hand file technique, appointment time for case completion was significantly decreased (P<.001) and overall radiographic quality of mandibular molar mesial root obturation was significantly increased (P=.0009). These results support the hypothesis that novice clinicians can perform endodontic therapy more efficiently when using a nickel titanium rotary file technique. In addition, no differences were noted in the incidence of file fracture when using rotary instruments.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16494095

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  5 in total

Review 1.  Impact of nickel-titanium instrumentation of the root canal on clinical outcomes: a focused review.

Authors:  Edgar Schäfer; Sebastian Bürklein
Journal:  Odontology       Date:  2012-04-22       Impact factor: 2.634

2.  Volumetric Assessment of Root Canal Obturation Using 3% Nano-Chitosan versus Zinc Oxide Eugenol (ZOE) and Iodoform-Calcium Hydroxide (Metapex), in Primary Root Canals Shaped with Rotary versus Manual Methods: A Preliminary In-Vitro Spiral CT Study.

Authors:  Elahe Babashahi; Maryam Mohmadi Kartalaie; Leila Basir; Vahid Rakhshan
Journal:  Front Dent       Date:  2019-01-20

3.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

4.  Comparative radiographic assessment of root canal obturation quality: manual verses rotary canal preparation technique.

Authors:  Ghafoor Robia
Journal:  Int J Biomed Sci       Date:  2014-06

5.  Radiographic assessment and chair time of rotary instruments in the pulpectomy of primary second molar teeth: a randomized controlled clinical trial.

Authors:  Abbas Makarem; Navid Ravandeh; Masoumeh Ebrahimi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-06-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.