Between-day repeatability and symmetry of multifidus cross-sectional area measured using ultrasound imaging.

Janel Frantz Pressler1, Deborah Givens Heiss, John A Buford, John V Chidley.   

Abstract

STUDY
DESIGN: Prospective test-retest, intrarater reliability study.
OBJECTIVES: To estimate the intrarater reliability, asymmetry, and associated error with measurement of the cross-sectional area (CSA) of the bilateral S1 multifidi when measured by a physical therapist following a short course of self-directed training in ultrasound imaging.
BACKGROUND: There is increasing interest in the assessment of the lumbar multifidus during the recovery from low back injury. It is important to know the error associated with the CSA measurements obtained by a physical therapist with limited experience in ultrasound imaging when using a portable unit. METHODS AND MEASURES: Thirty healthy females (mean +/- SD age, 23 +/- 2 years; mean +/- SD mass, 63.1 +/- 9.2 kg; mean +/- SD height, 1.63 +/- 0.06 m) participated. Fourteen subjects returned within 1 to 4 days for repeated measurements.
RESULTS: For all 30 subjects, the average (+/- SD) CSA of the left S1 multifidus (4.18 +/- 0.55 cm2) was larger (P<.05) than the right (4.11 +/- 0.57 cm2), with a standard error of the measurement (SEM) of 0.13 cm2 and average +/- SD asymmetry of 3.5% +/- 3.4%. For a subset of 14 subjects, the between-day intrarater reliability for the right S1 multifidus muscle was ICC3,1 = 0.80 (95% CI, 0.49-0.93), while the ICC for the left side was 0.72 (95% CI, 0.34-0.90). The day-to-day average differences for the left and right side were 0.02 cm2 and 0.04 cm2, respectively. For the most conservative estimate, the between-day SEM was 0.37cm2.
CONCLUSIONS: A physical therapist, newly trained in ultrasound imaging, obtained reasonable between-day intrarater reliability when imaging the S1 multifidus. A high degree of symmetry was found between the bilateral S1 multifidi in a sample of healthy subjects, which is consistent with previous reports from measurements by skilled ultrasonographers.

Entities:  

Mesh:

Year:  2006        PMID: 16494069     DOI: 10.2519/jospt.2006.36.1.10

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  15 in total

1.  Does pre-operative magnetic resonance imaging of the lumbar multifidus muscle predict clinical outcomes following lumbar spinal decompression for symptomatic spinal stenosis?

Authors:  Mario G T Zotti; F Vilas Boas; T Clifton; M Piche; W W Yoon; B J C Freeman
Journal:  Eur Spine J       Date:  2017-02-08       Impact factor: 3.134

Review 2.  Multifidus and paraspinal muscle group cross-sectional areas of patients with low back pain and control patients: a systematic review with a focus on blinding.

Authors:  Maryse Fortin; Luciana Gazzi Macedo
Journal:  Phys Ther       Date:  2013-03-15

3.  Ultrasound imaging: intraexaminer and interexaminer reliability for multifidus muscle thickness assessment in adults aged 60 to 85 years versus younger adults.

Authors:  J Megan Sions; Teonette O Velasco; Deydre S Teyhen; Gregory E Hicks
Journal:  J Orthop Sports Phys Ther       Date:  2014-04-25       Impact factor: 4.751

4.  Ipsilateral atrophy of paraspinal and psoas muscle in unilateral back pain patients with monosegmental degenerative disc disease.

Authors:  A Ploumis; N Michailidis; P Christodoulou; I Kalaitzoglou; G Gouvas; A Beris
Journal:  Br J Radiol       Date:  2010-11-16       Impact factor: 3.039

5.  Reliability and responsiveness of musculoskeletal ultrasound in subjects with and without spinal cord injury.

Authors:  Shauna Dudley-Javoroski; Tara McMullen; Michelle R Borgwardt; Lauren M Peranich; Richard K Shields
Journal:  Ultrasound Med Biol       Date:  2010-10       Impact factor: 2.998

6.  Self-Managed Exercises, Fitness and Strength Training, and Multifidus Muscle Size in Elite Footballers.

Authors:  Julie A Hides; Jazmin C Walsh; Melinda M Franettovich Smith; M Dilani Mendis
Journal:  J Athl Train       Date:  2017-05-01       Impact factor: 2.860

7.  The association of nutritional status and gender with cross-sectional area of the multifidus muscle in establishing normative data.

Authors:  Todd Watson; Sue McPherson; Kathy Starr
Journal:  J Man Manip Ther       Date:  2008

8.  Reliability of ultrasound imaging for the assessment of lumbar multifidi thickness in older adults with chronic low back pain.

Authors:  J Megan Sions; Teonette O Velasco; Deydre S Teyhen; Gregory E Hicks
Journal:  J Geriatr Phys Ther       Date:  2015 Jan-Mar       Impact factor: 3.381

9.  Criterion Validity of Ultrasound Imaging: Assessment of Multifidi Cross-Sectional Area in Older Adults With and Without Chronic Low Back Pain.

Authors:  Jaclyn Megan Sions; Deydre S Teyhen; Gregory E Hicks
Journal:  J Geriatr Phys Ther       Date:  2017 Apr/Jun       Impact factor: 3.381

10.  Trunk Muscle Size and Composition Assessment in Older Adults with Chronic Low Back Pain: An Intra-Examiner and Inter-Examiner Reliability Study.

Authors:  Jaclyn Megan Sions; Andrew Craig Smith; Gregory Evan Hicks; James Matthew Elliott
Journal:  Pain Med       Date:  2015-12-07       Impact factor: 3.750

View more