Literature DB >> 16493102

Sirolimus- vs paclitaxel-eluting stents in de novo coronary artery lesions: the REALITY trial: a randomized controlled trial.

Marie-Claude Morice1, Antonio Colombo, Bernhard Meier, Patrick Serruys, Corrado Tamburino, Giulio Guagliumi, Eduardo Sousa, Hans-Peter Stoll.   

Abstract

CONTEXT: Compared with bare metal stents, sirolimus-eluting and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been compared in a prospective multicenter study.
OBJECTIVE: To compare the safety and efficacy of sirolimus-eluting vs paclitaxel-eluting coronary stents.
DESIGN: Prospective, randomized comparative trial (the REALITY trial) conducted between August 2003 and February 2004, with angiographic follow-up at 8 months and clinical follow-up at 12 months.
SETTING: Ninety hospitals in Europe, Latin America, and Asia. PATIENTS: A total of 1386 patients (mean age, 62.6 years; 73.1% men; 28.0% with diabetes) with angina pectoris and 1 or 2 de novo lesions (2.25-3.00 mm in diameter) in native coronary arteries. INTERVENTION: Patients were randomly assigned in a 1:1 ratio to receive a sirolimus-eluting stent (n = 701) or a paclitaxel-eluting stent (n = 685). MAIN OUTCOME MEASURES: The primary end point was in-lesion binary restenosis (presence of a more than 50% luminal-diameter stenosis) at 8 months. Secondary end points included 1-year rates of target lesion and vessel revascularization and a composite end point of cardiac death, Q-wave or non-Q-wave myocardial infarction, coronary artery bypass graft surgery, or repeat target lesion revascularization.
RESULTS: In-lesion binary restenosis at 8 months occurred in 86 patients (9.6%) with a sirolimus-eluting stent vs 95 (11.1%) with a paclitaxel-eluting stent (relative risk [RR], 0.84; 95% confidence interval [CI], 0.61-1.17; P = .31). For sirolimus- vs paclitaxel-eluting stents, respectively, the mean (SD) in-stent late loss was 0.09 (0.43) mm vs 0.31 (0.44) mm (difference, -0.22 mm; 95% CI, -0.26 to -0.18 mm; P<.001), mean (SD) in-stent diameter stenosis was 23.1% (16.6%) vs 26.7% (15.8%) (difference, -3.60%; 95% CI, -5.12% to -2.08%; P<.001), and the number of major adverse cardiac events at 1 year was 73 (10.7%) vs 76 (11.4%) (RR, 0.94; 95% CI, 0.69-1.27; P = .73).
CONCLUSION: In this trial comparing sirolimus- and paclitaxel-eluting coronary stents, there were no differences in the rates of binary restenosis or major adverse cardiac events. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00235092.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16493102     DOI: 10.1001/jama.295.8.895

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  50 in total

1.  Evaluation of coronary artery in-stent restenosis with prospectively ECG-triggered axial CT angiography versus retrospective technique: a phantom study.

Authors:  W-J Yang; Z-L Pan; H Zhang; L-F Pang; Y Guo; K-M Chen
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

2.  Risk of stent thrombosis after sirolimus or paclitaxel eluting coronary stent implantation.

Authors:  Raul Moreno; Cristina Fernandez; Angel Sanchez-Recalde; Luis Calvo; Guillermo Galeote; Rosa Sanchez-Aquino; Jose-Luis Lopez-Sendon
Journal:  Br J Clin Pharmacol       Date:  2007-07       Impact factor: 4.335

3.  The Sirolimus-eluting coronary stent in daily routine practice in Germany: trends in indications over the years. Results from the prospective multi-centre German Cypher Stent Registry.

Authors:  Ralf Zahn; C W Hamm; S Schneider; U Zeymer; G Richardt; M Kelm; B Levenson; T Bonzel; U Tebbe; G Sabin; C A Nienaber; Thomas Pfannebecker; J Senges
Journal:  Clin Res Cardiol       Date:  2007-06-04       Impact factor: 5.460

4.  The paclitaxel-eluting Coroflex Please stent pilot study (PECOPS I) : the one-year clinical follow-up.

Authors:  Martin Unverdorben; Ralf Degenhardt; Marcus Wiemer; Dieter Horstkotte; Henrik Schneider; Christoph Nienaber; Wolfgang Bocksch; Michael Gross; Michael Boxberger; Christian Vallbracht
Journal:  Clin Res Cardiol       Date:  2007-08-23       Impact factor: 5.460

5.  Treatment of small coronary arteries with a paclitaxel-coated balloon catheter.

Authors:  Martin Unverdorben; Franz X Kleber; Hubertus Heuer; Hans-Reiner Figulla; Christian Vallbracht; Matthias Leschke; Bodo Cremers; Stefan Hardt; Michael Buerke; Hanns Ackermann; Michael Boxberger; Ralf Degenhardt; Bruno Scheller
Journal:  Clin Res Cardiol       Date:  2010-01-06       Impact factor: 5.460

6.  The use of the GuideLiner™ catheter as a child-in-mother technique: an initial single-center experience.

Authors:  Petros S Dardas; Nikos Mezilis; Vlasis Ninios; Dimitrios Tsikaderis; Efstratios K Theofilogiannakos
Journal:  Heart Vessels       Date:  2011-08-25       Impact factor: 2.037

7.  Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography.

Authors:  Yung-Liang Wan; Pei-Kwei Tsay; Chun-Chi Chen; Yu-Hsiang Juan; Yu-Chieh Huang; Wen-Hui Chan; Ming-Shien Wen; I-Chang Hsieh
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-22       Impact factor: 2.357

8.  Inhibitory effects of roscovitine on proliferation and migration of vascular smooth muscle cells in vitro.

Authors:  Shuang-Shuang Zhang; Wei Wang; Chong-Qiang Zhao; Min-Jie Xie; Wen-Yu Li; Xiang-Li Yang; Jia-Gao Lv
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-12-06

9.  Coronary pressure measurement based decision making for percutaneous coronary intervention.

Authors:  Kohichiro Iwasaki; Shozo Kusachi
Journal:  Curr Cardiol Rev       Date:  2009-11

10.  Comparison of sirolimus and paclitaxel-eluting stents for complex coronary lesions: an intravascular ultrasound study.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur; Hyun-Tae Kim; In-Cheol Kim; Hyoung-Seob Park; Hyuck-Jun Yoon; Chang-Wook Nam; Hyungseop Kim; Seong-Wook Han; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean J Intern Med       Date:  2009-11-27       Impact factor: 2.884