Literature DB >> 1649195

Osteolytic changes accompanying degradation of absorbable fracture fixation implants.

O M Böstman1.   

Abstract

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1649195

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  31 in total

1.  Complications of bioresorbable fixation systems in pediatric neurosurgery.

Authors:  Cherukuri Ravi Kumar; Sandeep Sood; Steven Ham
Journal:  Childs Nerv Syst       Date:  2004-07-29       Impact factor: 1.475

2.  Absorbable implants for open shoulder stabilization. A 7-8-year clinical and radiographic follow-up.

Authors:  Lennart Magnusson; Lars Ejerhed; Lars Rostgård; Ninni Sernert; Jüri Kartus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-08-27       Impact factor: 4.342

3.  Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction.

Authors:  Krzysztof Gaweda; Jacek Walawski; Robert Wegłowski; Wojciech Krzyzanowski
Journal:  Int Orthop       Date:  2007-12-07       Impact factor: 3.075

4.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

Review 5.  Nanostructured platforms for the sustained and local delivery of antibiotics in the treatment of osteomyelitis.

Authors:  Vuk Uskokovic
Journal:  Crit Rev Ther Drug Carrier Syst       Date:  2015       Impact factor: 4.889

6.  High long-term survival of bulk femoral head autograft for acetabular reconstruction in cementless THA for developmental hip dysplasia.

Authors:  Mitsunari Kim; Toru Kadowaki
Journal:  Clin Orthop Relat Res       Date:  2010-03-23       Impact factor: 4.176

7.  [Imaging of postarthroscopic complications after knee injuries].

Authors:  C Schueller-Weidekamm; G von Skrbensky
Journal:  Radiologe       Date:  2012-11       Impact factor: 0.635

8.  Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide. A clinical study.

Authors:  T Yamamuro; Y Matsusue; A Uchida; K Shimada; E Shimozaki; K Kitaoka
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

9.  Osteogenic and antimicrobial nanoparticulate calcium phosphate and poly-(D,L-lactide-co-glycolide) powders for the treatment of osteomyelitis.

Authors:  Vuk Uskoković; Charles Hoover; Marija Vukomanović; Dragan P Uskoković; Tejal A Desai
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2013-04-13       Impact factor: 7.328

10.  A biodegradable antibiotic delivery system based on poly-(trimethylene carbonate) for the treatment of osteomyelitis.

Authors:  Daniëlle Neut; Otto S Kluin; Bart J Crielaard; Henny C van der Mei; Henk J Busscher; Dirk W Grijpma
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.