Literature DB >> 16491173

Rapid trace detection of triacetone triperoxide (TATP) by complexation reactions during desorption electrospray ionization.

Ismael Cotte-Rodríguez1, Hao Chen, R Graham Cooks.   

Abstract

Desorption electrospray ionization (DESI) mass spectrometry is used for rapid, specific and sensitive detection of trace amounts of the notorious explosive TATP present on ambient surfaces by alkali metal complexation in a simple spray technique.

Entities:  

Year:  2006        PMID: 16491173     DOI: 10.1039/b515122h

Source DB:  PubMed          Journal:  Chem Commun (Camb)        ISSN: 1359-7345            Impact factor:   6.222


  20 in total

1.  Analysis of lipids from crude lung tissue extracts by desorption electrospray ionization mass spectrometry and pattern recognition.

Authors:  Franco Basile; Tamara Sibray; John T Belisle; Richard A Bowen
Journal:  Anal Biochem       Date:  2010-09-22       Impact factor: 3.365

2.  Multivariate statistical identification of human bladder carcinomas using ambient ionization imaging mass spectrometry.

Authors:  Allison L Dill; Livia S Eberlin; Anthony B Costa; Cheng Zheng; Demian R Ifa; Liang Cheng; Timothy A Masterson; Michael O Koch; Olga Vitek; R Graham Cooks
Journal:  Chemistry       Date:  2011-01-31       Impact factor: 5.236

3.  Desorption electrospray ionization-mass spectrometry of proteins.

Authors:  Yong-Seung Shin; Barbara Drolet; Richard Mayer; Kurt Dolence; Franco Basile
Journal:  Anal Chem       Date:  2007-03-30       Impact factor: 6.986

4.  Internal energy distributions in desorption electrospray ionization (DESI).

Authors:  Marcela Nefliu; Jonell N Smith; Andre Venter; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2007-12-04       Impact factor: 3.109

5.  Neutral desorption using a sealed enclosure to sample explosives on human skin for rapid detection by EESI-MS.

Authors:  Huanwen Chen; Bin Hu; Yan Hu; Yanfu Huan; Zhiquan Zhou; Xiaolin Qiao
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-27       Impact factor: 3.109

6.  Implementation of DART and DESI ionization on a fieldable mass spectrometer.

Authors:  J Mitchell Wells; Michael J Roth; Adam D Keil; John W Grossenbacher; Dina R Justes; Garth E Patterson; Dennis J Barket
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-18       Impact factor: 3.109

7.  Direct analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS).

Authors:  Zhixin Miao; Hao Chen
Journal:  J Am Soc Mass Spectrom       Date:  2008-09-30       Impact factor: 3.109

Review 8.  What can we learn from ambient ionization techniques?

Authors:  Huanwen Chen; Gerardo Gamez; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-13       Impact factor: 3.109

9.  On-Probe Pyrolysis Desorption Electrospray Ionization (DESI) Mass Spectrometry for the Analysis of Non-Volatile Pyrolysis Products.

Authors:  Shaofeng Zhang; Yong-Seung Shin; Richard Mayer; Franco Basile
Journal:  J Anal Appl Pyrolysis       Date:  2007-01-10       Impact factor: 5.541

10.  Reactions of Organic Peroxides with Alcohols in Atmospheric Pressure Chemical Ionization-the Pitfalls of Quantifying Triacetone Triperoxide (TATP).

Authors:  Kevin Colizza; Alexander Yevdokimov; Lindsay McLennan; James L Smith; Jimmie C Oxley
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-07       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.