OBJECTIVE: The aim of this study was to evaluate clinical and radiological outcomes of the unsplinted implants supporting mandibular overdenture when applying conventional or early loading protocols.
MATERIAL AND METHODS: Twenty-six edentulous patients were treated with two unsplinted Brånemark System implants supporting mandibular overdenture. There was a test group, in which the overdenture was connected 1 week after surgery, and a control group, in which the overdenture was connected 3 months after surgery. Peri-implant parameters were recorded 1, 6, and 12 months after surgery. Clinical stability measurements were performed at surgery, and after 3, 6, and 12 months. Marginal bone levels were evaluated at implant surgery, after 6, and after 12 months.
RESULTS: No implant from either group was lost. Clinical peri-implant parameters, clinical stability measurements, and marginal bone resorptions showed no statistically significant differences between two groups during 12 months.
CONCLUSION: The results of this study suggest that one-week of early loading protocol of two Brånemark implants supporting mandibular overdenture does not compromise implant stability, marginal bone loss, and peri-implant soft-tissue health.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16489951     DOI: 10.1111/j.1600-051X.2006.00895.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  6 in total

Review 1.  Implants in bone: part I. A current overview about tissue response, surface modifications and future perspectives.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-24

Review 2.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

3.  Influence of bone density on implant stability parameters and implant success: a retrospective clinical study.

Authors:  Ilser Turkyilmaz; Edwin A McGlumphy
Journal:  BMC Oral Health       Date:  2008-11-24       Impact factor: 2.757

4.  Evaluation of peri-implant soft tissue and bone levels around early loaded implant in restoring single missing tooth: A clinico-radiographic study.

Authors:  Isha Bhardwaj; Anoop Bhushan; Chandrababu Sudha Baiju; Shweta Bali; Vaibhav Joshi
Journal:  J Indian Soc Periodontol       Date:  2016 Jan-Feb

5.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

6.  Image-based Bone Density Classification Using Fractal Dimensions and Histological Analysis of Implant Recipient Site.

Authors:  Elie Hayek; Georges Aoun; Hassem Geha; Ibrahim Nasseh
Journal:  Acta Inform Med       Date:  2020-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.