BACKGROUND: In pediatric patients, several studies have been undertaken to establish central venous catheter (CVC) tip optimal depth. Assessments of catheter tip position using chest radiographs may be misleading, whereas transesophageal echocardiography (TEE) has been shown to accurately monitor catheter tip placement at the superior vena cava-right atrial (SVC-RA) junction. The aim of this study was to issue a guideline for ideal catheter insertion depth, from the right internal jugular vein (IJV) using TEE to confirm the position of the catheter tip at the SVC-RA junction.
METHODS: Over a 6-month period, we studied 60 right internal jugular vein catheterizations in infants and children undergoing surgery for congenital heart disease. Positions of CVC tips were confirmed to be at the SVC-RA junction by TEE. Distance from the skin puncture site to the SVC-RA junction, height, weight, and age were recorded.
RESULTS: Distances measured were found to be highly correlated with patient height. The following guideline allows the CVC tip to be positioned above the RA in 97.5% of patients with an accuracy of 95%: optimal depth of insertion (cm) = 1.7 + (0.07 x height) in patients whose height is between 40 and 140 cm.
CONCLUSION: The model proposed for the insertion of the CVC tip in pediatric patients could be used to prevent inadvertent catheter tip placement into the atrium.

Entities:  

Mesh:

Year:  2006        PMID: 16480470     DOI: 10.1111/j.1399-6576.2006.00951.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  8 in total

1.  [Correct positioning of central venous catheters in pediatrics : Are current formulae really useful?]

Authors:  C Cleff; M Boensch; F Eifinger; J Hinkelbein
Journal:  Anaesthesist       Date:  2018-07       Impact factor: 1.041

Review 2.  [Avoidance of complications when dealing with central venous catheters in the treatment of children].

Authors:  D Aprili; T O Erb
Journal:  Anaesthesist       Date:  2017-04       Impact factor: 1.041

3.  Retrospective Assessment of Patient and Catheter Characteristics Associated With Malpositioned Central Venous Catheters in Pediatric Patients.

Authors:  Mark D Weber; Thomas Conlon; Charlotte Woods-Hill; Stephanie L Watts; Eileen Nelson; Danielle Traynor; Bingqing Zhang; Daniela Davis; Adam S Himebauch
Journal:  Pediatr Crit Care Med       Date:  2022-03-01       Impact factor: 3.624

4.  A CT scan-based formula for predicting central venous catheter length in pediatric patients.

Authors:  Aaron B Ross; Oswaldo Gomez-Quevedo; Pattamon Sutthatarn; Zhaohua Lu; Xiaoqing Wang; Hasmukh Prajapati; Lindsay J Talbot; Andrew M Davidoff; Andrew J Murphy; Abdelhafeez H Abdelhafeez
Journal:  Pediatr Surg Int       Date:  2022-07-18       Impact factor: 2.003

5.  Comparative Study of Three Methods for Depth of Central Venous Catheter Placement in Children: An Observational Pilot Study.

Authors:  Vaishali Chaskar; Priyanka Pradeep Karnik; Nandini Malay Dave; Madhu Garasia
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-04-01

6.  Incidents and complications of totally implanted vascular access devices in children: a prospective study.

Authors:  Stéphane Tercier; Christophe Gapany; Manuel Diezi; Chantal Clément; Katy Lemay; Jean-Marc Joseph
Journal:  Patient Saf Surg       Date:  2008-11-13

7.  A comparative study of two techniques (electrocardiogram- and landmark-guided) for correct depth of the central venous catheter placement in paediatric patients undergoing elective cardiovascular surgery.

Authors:  Neeraj Kumar Barnwal; Sona T Dave; Raylene Dias
Journal:  Indian J Anaesth       Date:  2016-07

8.  Intelligent Internet of Things Medical Technology in Implantable Intravenous Infusion Port in Children with Malignant Tumors.

Authors:  Shaohong Liu; Luxing Jiang; Xin Wang
Journal:  J Healthc Eng       Date:  2021-11-28       Impact factor: 2.682

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.