AcrySof Natural SN60AT versus AcrySof SA60AT intraocular lens in patients with color vision defects.

Shetal M Raj1, Abhay R Vasavada, Mayank A Nanavaty.   

Abstract

PURPOSE: To determine whether implantation of the AcrySof Natural intraocular lens (IOL) worsened the severity of existing color deficit in congenital partial red-green color deficient individuals (CPRG).
METHODS: A prospective controlled randomized double-masked analysis of 30 consecutive patients with CPRG defect and bilateral cataracts received a Natural IOL (test group) in 1 eye and a single-piece AcrySof IOL (control group) in the other eye. Patients were tested unilaterally to detect CPRG defect using Ishihara pseudoisochromatic plates and the Farnsworth D-15 test. Plates 1 to 21 measured the Ishihara error score; plates 22 to 25 indicated severity of defect based on clarity of both numerals as partial mild/moderate (both visible), partial severe defect (only 1 visible). The D-15 test is based on number of diametrical crossings on the circular diagram; severity is graded as mild (1 crossing), moderate (2 crossings), or severe (>2 crossings). Tests were performed before and after IOL implantation at 1, 3, and 6 months. At mean follow-up of 6.13 months +/- 1.2 (SD), analysis of variance test judged the difference in error scores and cross tabulation represented change in number of diametrical crossings.
RESULTS: The mean age was 62.3 +/- 8.5 years. All patients were men. Before IOL implantation, all patients had moderate CPRG defect on both tests. The Ishihara error score in the test and control groups did not reveal statistically significant differences (P = .505 and P = .119, respectively). With D-15, none of the patients in the test or control group showed >2 crossings.
CONCLUSION: The implantation of AcrySof Natural IOL did not worsen the preexisting severity of color defect in CPRG individuals.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16473225     DOI: 10.1016/j.jcrs.2005.08.052

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Effect on contrast sensitivity after clear, yellow and orange intraocular lens implantation.

Authors:  Sabyasachi Bandyopadhyay; Mita Saha; Asim Chakrabarti; Abhik Sinha
Journal:  Int Ophthalmol       Date:  2015-08-19       Impact factor: 2.031

Review 2.  Ultraviolet or blue-filtering intraocular lenses: what is the evidence?

Authors:  S M Downes
Journal:  Eye (Lond)       Date:  2016-01-08       Impact factor: 3.775

Review 3.  Recent studies provide an updated clinical perspective on blue light-filtering IOLs.

Authors:  James A Davison; Anil S Patel; Joao P Cunha; Jim Schwiegerling; Orkun Muftuoglu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-05-17       Impact factor: 3.117

Review 4.  Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

Authors:  Laura E Downie; Ljoudmila Busija; Peter R Keller
Journal:  Cochrane Database Syst Rev       Date:  2018-05-22

5.  Psychophysical Measurements of Luminance Contrast Sensitivity and Color Discrimination with Transparent and Blue-Light Filter Intraocular Lenses.

Authors:  Marcelo Fernandes da Costa; Augusto Paranhos Júnior; Claudio Luiz Lottenberg; Leonardo Cunha Castro; Dora Fix Ventura
Journal:  Ophthalmol Ther       Date:  2017-08-09