Evaluating microcirculation by pulsatile laser Doppler signal.

P T Chao1, M Y Jan, H Hsiu, T L Hsu, W K Wang, Y Y Lin Wang.   

Abstract

Laser Doppler flowmetry (LDF) is a popular method for monitoring the microcirculation, but it does not provide absolute measurements. Instead, the mean flux response or energy distribution in the frequency domain is generally compared before and after stimulus. Using the heartbeat as a trigger, we investigated whether the relation between pressure and flux can be used to discriminate different microcirculatory conditions. We propose the following three pulsatile indices for evaluating the microcirculation condition from the normalized pressure and flux segment with a synchronized-averaging method: peak delay time (PDT), pressure rise time and flux rise time (FRT). The abdominal aortic blood pressure and renal cortex flux (RCF) signals were measured in spontaneously hypertensive rats (SHR) and Wistar Kyoto rats (WKY). The mean value of the RCF did not differ between SHR and WKY. However, the PDT was longer in SHR (87.14 +/- 5.54 ms, mean +/- SD) than in WKY (76.92 +/- 2.62 ms; p < 0.001). The FRT was also longer in SHR (66.56 +/- 1.98 ms) than in WKY (58.02 +/- 1.77 ms; p < 0.001). We propose that a new dimension for comparing the LDF signals, which the results from the present study show, can be used to discriminate RCF signals that cannot be discriminated using traditional methods.

Entities:  

Mesh:

Year:  2006        PMID: 16467582     DOI: 10.1088/0031-9155/51/4/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Effects of acupuncture at the Hoku acupoint on the pulsatile laser Doppler signal at the heartbeat frequency.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Chia-Liang Hsu; Ming-Yie Jan; Yuh-Ying Wang-Lin
Journal:  Lasers Med Sci       Date:  2008-09-09       Impact factor: 3.161

2.  Spectral analysis of the microcirculatory laser Doppler signal at the Hoku acupuncture point.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Shih-Ming Huang; Chia-Liang Hsu; Yuh-Ying Lin Wang
Journal:  Lasers Med Sci       Date:  2008-05-27       Impact factor: 3.161

3.  Assessing the effects of acupuncture by comparing needling the hegu acupoint and needling nearby nonacupoints by spectral analysis of microcirculatory laser Doppler signals.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Chia-Liang Hsu; Shih-Min Huang
Journal:  Evid Based Complement Alternat Med       Date:  2011-06-16       Impact factor: 2.629

4.  A novel assessment of flexibility by microcirculatory signals.

Authors:  Jian-Guo Bau; Taipau Chia; Yu-Fang Chung; Kun-Hao Chen; Shyi-Kuen Wu
Journal:  Sensors (Basel)       Date:  2013-12-30       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.