Literature DB >> 16464670

An anthropomorphic tissue-mimicking phantom of the oesophagus for endoscopic ultrasound.

Scott Inglis1, Kumar V Ramnarine, John N Plevris, W Norman McDicken.   

Abstract

This study details the design and construct of an anthropomorphic phantom of the oesophagus suitable for use with endoscopic ultrasound (EUS) and 3-D volume measurements. The phantom was constructed using agar-based tissue-mimicking material (TMM) of different acoustical properties to simulate various anatomical and pathologic features. The acoustical properties were measured with a scanning acoustical macroscope. An Olympus GF-UM200 echo-endoscope and digital position measurement arm were used to scan the phantom at 7.5 and 12 MHz. Comparative dimensional measurements were performed on the phantom via 2-D and 3-D EUS. TMM attenuation varied between 0.1 and 0.5 dB/cm.MHz. Backscatter power, relative to normal TMM, was from 0 to -12.2 dB, with an average speed of sound of 1537 +/- 1.9 m/s. Measurements of objects within the phantom by 2-D and 3-D EUS had mean errors of 8% and 2.2%, respectively. The construction of the anthropomorphic EUS phantom facilitated EUS training and research and development studies.

Entities:  

Mesh:

Year:  2006        PMID: 16464670     DOI: 10.1016/j.ultrasmedbio.2005.10.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.

Authors:  Adam D Maxwell; Tzu-Yin Wang; Lingqian Yuan; Alexander P Duryea; Zhen Xu; Charles A Cain
Journal:  Ultrasound Med Biol       Date:  2010-10-28       Impact factor: 2.998

2.  Quantitative sparse array vascular elastography: the impact of tissue attenuation and modulus contrast on performance.

Authors:  Steven Huntzicker; Rohit Nayak; Marvin M Doyley
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-04

3.  The design and fabrication of two portal vein flow phantoms by different methods.

Authors:  Bryan E Yunker; Gerald D Dodd; S James Chen; Samuel Chang; Craig J Lanning; Ann L Scherzinger; Robin Shandas; Yusheng Feng; Kendall S Hunter
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

Review 4.  3D Printed Organ Models for Surgical Applications.

Authors:  Kaiyan Qiu; Ghazaleh Haghiashtiani; Michael C McAlpine
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2018-03-28       Impact factor: 10.745

5.  The speed of sound and attenuation of an IEC agar-based tissue-mimicking material for high frequency ultrasound applications.

Authors:  Chao Sun; Stephen D Pye; Jacinta E Browne; Anna Janeczko; Bill Ellis; Mairead B Butler; Vassilis Sboros; Adrian J W Thomson; Mark P Brewin; Charles H Earnshaw; Carmel M Moran
Journal:  Ultrasound Med Biol       Date:  2012-04-12       Impact factor: 2.998

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.