Literature DB >> 16463354

Fast low-angle dual spin-echo (FLADE): a new robust pulse sequence for structural imaging of trabecular bone.

J Magland1, B Vasilic, F W Wehrli.   

Abstract

Mechanical strength and fracture resistance of trabecular bone (TB) are largely determined by the structural arrangement of individual trabeculae. Fast 3D spin-echo approaches are preferable to gradient echoes in that they are less sensitive to local induced gradients at the bone/marrow interface caused by magnetic susceptibility difference between the two tissues. FLASE is a 3D pulse sequence that serves this purpose. Here, we present a new pulse sequence dubbed FLADE (fast low-angle dual spin-echo) that overcomes some of the limitations inherent to FLASE, such as sensitivity to artifactual stimulated echoes. The double-echo sequence features a flip angle <90 degrees allowing for TR << T(1). The second phase-reversal pulse has the dual function of creating a second echo and restoring inverted longitudinal magnetization. The prolonged TR, made possible by sampling only half of k(z)-space, is used to collect navigator echoes in adjacent slabs for sensing subpixel translational displacements. FLADE is shown to provide SNR comparable to FLASE while having narrower point-spread function and being more robust to imperfections in the nonselective 180 degree pulses. Structural parameters derived from the in vivo images with the two pulse sequences are highly correlated, therefore suggesting that clinical data obtained with either pulse sequence can be merged. Magn Reson Med, 2006. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16463354     DOI: 10.1002/mrm.20789

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  Noninvasive assessment of bone microarchitecture by MRI.

Authors:  Glenn A Ladinsky; Felix W Wehrli
Journal:  Curr Osteoporos Rep       Date:  2006-12       Impact factor: 5.096

2.  Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T.

Authors:  Alexander C Wright; Rostislav Lemdiasov; Thomas J Connick; Yusuf A Bhagat; Jeremy F Magland; Hee Kwon Song; Steven P Toddes; Reinhold Ludwig; Felix W Wehrli
Journal:  J Magn Reson       Date:  2011-02-23       Impact factor: 2.229

3.  MRI of trabecular bone using a decay due to diffusion in the internal field contrast imaging sequence.

Authors:  Dionyssios Mintzopoulos; Jerome L Ackerman; Yi-Qiao Song
Journal:  J Magn Reson Imaging       Date:  2011-08       Impact factor: 4.813

Review 4.  MRI-based mechanical competence assessment of bone using micro finite element analysis (micro-FEA): Review.

Authors:  Saeed Jerban; Salem Alenezi; Amir Masoud Afsahi; Yajun Ma; Jiang Du; Christine B Chung; Eric Y Chang
Journal:  Magn Reson Imaging       Date:  2022-01-25       Impact factor: 2.546

5.  Validation of oxygen extraction fraction measurement by qBOLD technique.

Authors:  Xiang He; Mingming Zhu; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

6.  Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE).

Authors:  J F Magland; M J Wald; F W Wehrli
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

7.  Solid-state 31P and 1H chemical MR micro-imaging of hard tissues and biomaterials with magic angle spinning at very high magnetic field.

Authors:  Maxime Yon; Vincent Sarou-Kanian; Ulrich Scheler; Jean-Michel Bouler; Bruno Bujoli; Dominique Massiot; Franck Fayon
Journal:  Sci Rep       Date:  2017-08-15       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.