Literature DB >> 16461494

Dose conversion coefficients for interventional procedures.

F W Schultz1, J Zoetelief.   

Abstract

Effective dose (E) is a convenient quantity to estimate the stochastic risk of radiation applied to patients in interventional procedures and can be used for optimisation. Relatively long exposure times may cause deterministic effects. Hence it is necessary to know the (maximum local) doses in organs owing to the interventional procedure. In practice, organ doses cannot be measured directly. They are derived by applying a conversion coefficient to a measurable quantity, e.g. dose-area product (DAP) or entrance skin dose. For a number of interventional procedures, dose conversion coefficients (DCCs) can be found in the literature. Various DCCs are stated for nominally equal procedures, e.g. for percutaneous transluminal coronary angioplasty both 0.18 and 0.27 mSv Gy(-1) cm(-2) were reported to convert DAP to effective dose. Dependence of DCC on protocol and equipment parameters, as demonstrated through Monte Carlo simulation in this paper, makes it hazardous to simply adopt a literature value.

Entities:  

Mesh:

Year:  2006        PMID: 16461494     DOI: 10.1093/rpd/nci753

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Effective-dose estimation in interventional radiological procedures.

Authors:  Maria D Falco; Salvatore Masala; Matteo Stefanini; Paolo Bagalà; Daniele Morosetti; Eros Calabria; Alessia Tonnetti; Gianluca Verona-Rinati
Journal:  Radiol Phys Technol       Date:  2018-03-08

2.  Radiation doses to the population of the Emilia-Romagna region from medical exposures.

Authors:  G Compagnone; P Angelini; S Domenichelli
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

3.  Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye.

Authors:  B Oude Velthuis; M Molenaar; H G Reinhart Dorman; J Y Stevenhagen; M F Scholten; J van der Palen; J M van Opstal
Journal:  Neth Heart J       Date:  2017-06       Impact factor: 2.380

4.  Conversion coefficients for the estimation of effective dose in cone-beam CT.

Authors:  Dong-Soo Kim; Oyuntugs Rashsuren; Eun-Kyung Kim
Journal:  Imaging Sci Dent       Date:  2014-03-19

5.  Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.

Authors:  Ji Hyun Lee; Jun Kim; Minsu Kim; Jongmin Hwang; You Mi Hwang; Joon-Won Kang; Gi-Byoung Nam; Kee-Joon Choi; You-Ho Kim
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.