Literature DB >> 16458782

Monte Carlo-based dosimetry of head-and-neck patients treated with SIB-IMRT.

Nirmal Sakthi1, Paul Keall, Ivaylo Mihaylov, Qiuwen Wu, Yan Wu, Jeffrey F Williamson, Rupert Schmidt-Ullrich, Jeffrey V Siebers.   

Abstract

PURPOSE: To evaluate the accuracy of previously reported superposition/convolution (SC) dosimetric results by comparing with Monte Carlo (MC) dose calculations for head-and-neck intensity-modulated radiation therapy (IMRT) patients treated with the simultaneous integrated boost technique. METHODS AND MATERIALS: Thirty-one plans from 24 patients previously treated on a phase I/II head-and-neck squamous cell carcinoma simultaneous integrated boost IMRT protocol were used. Clinical dose distributions, computed with an SC algorithm, were recomputed using an EGS4-based MC algorithm. Phantom-based dosimetry quantified the fluence prediction accuracy of each algorithm. Dose-volume indices were used to compare patient dose distributions. RESULTS AND DISCUSSION: The MC algorithm predicts flat-phantom measurements better than the SC algorithm. Average patient dose indices agreed within 2.5% of the local dose for targets; 5.0% for parotids; and 1.9% for cord and brainstem. However, only 1 of 31 plans agreed within 3% for all indices; 4 of 31 agreed within 5%. In terms of the prescription dose, 4 of 31 plans agreed within 3% for all indices, whereas 28 of 31 agreed within 5%.
CONCLUSIONS: Average SC-computed doses agreed with MC results in the patient geometry; however deviations >5% were common. The fluence modulation prediction is likely the major source of the dose discrepancy. The observed dose deviations can impact dose escalation protocols, because they would result in shifting patients to higher dose levels.

Entities:  

Mesh:

Year:  2006        PMID: 16458782     DOI: 10.1016/j.ijrobp.2005.09.049

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  9 in total

1.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

2.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01

3.  Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm.

Authors:  I B Mihaylov; J V Siebers
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

4.  Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the Collapsed Cone Convolution algorithm for head and neck cancers.

Authors:  Duong Thanh Tai; Luong Thi Oanh; Nguyen Dong Son; Truong Thi Hong Loan; James C L Chow
Journal:  Rep Pract Oncol Radiother       Date:  2018-11-28

5.  Improved normal tissue sparing in head and neck radiotherapy using biological cost function based-IMRT.

Authors:  N Anderson; C Lawford; V Khoo; M Rolfo; D L Joon; M Wada
Journal:  Technol Cancer Res Treat       Date:  2011-12

6.  Development and validation of MCNPX-based Monte Carlo treatment plan verification system.

Authors:  Iraj Jabbari; Shahram Monadi
Journal:  J Med Phys       Date:  2015 Apr-Jun

7.  Evaluation of dose prediction error and optimization convergence error in four-dimensional inverse planning of robotic stereotactic lung radiotherapy.

Authors:  Mark K H Chan; Dora L W Kwong; Anthony Tong; Eric Tam; Sherry C Y Ng
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

8.  Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning.

Authors:  Vladimir Feygelman; Kujtim Latifi; Mark Bowers; Kevin Greco; Eduardo G Moros; Max Isacson; Agnes Angerud; Jimmy Caudell
Journal:  J Appl Clin Med Phys       Date:  2022-02-25       Impact factor: 2.243

9.  Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy.

Authors:  Nesrin Dogan; Ivaylo Mihaylov; Yan Wu; Paul J Keall; Jeffrey V Siebers; Michael P Hagan
Journal:  Radiat Oncol       Date:  2009-06-15       Impact factor: 3.481

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.