LASIK for hyperopia with the WaveLight excimer laser.

A John Kanellopoulos1, Joseph Conway, Lawrence H Pe.   

Abstract

PURPOSE: To evaluate the safety and efficacy of the ALLEGRETTO WAVE excimer laser system (WaveLight Laser Technologie AG, Erlangen, Germany) in LASIK for hyperopia and hyperopic astigmatism.
METHODS: One hundred twenty consecutive LASIK cases for hyperopia with or without astigmatism treated with the ALLEGRETTO WAVE excimer laser were prospectively evaluated up to 12 months postoperatively. Patients were allocated into three groups according to their refractive sphere and cylinder: a low hyperopia group, with up to +3.00 diopters (D) sphere and astigmatism < or = +1.00 D (n = 52); a moderate hyperopia group with +3.25 to +5.00 D sphere and astigmatism of < or = +1.00 D (n = 45); and a high hyperopia/toric group with sphere > or = +5.25 D or cylinder > or = +1.25.D (n = 23). Flaps were created with the Moria M2 microkeratome (Moria, Antony, France). Parameters evaluated were pre- and postoperative refractive error, uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), higher order aberration change, and contrast sensitivity.
RESULTS: One hundred twelve eyes (93%) were available for follow-up at 12 months. Of the eyes in the low hyperopia group, 92% were within +/- 0.50 D of the refractive goal. For the moderate sphere group and the high hyperopia/toric group, 79% and 71% of eyes, respectively, were within +/- 0.50 D of the refractive goal. No eye lost > or = 2 lines of BSCVA. An increase in higher order aberrations was noted in the high hyperopia/toric group from 0.47 microm (+/- 0.096) to 0.94 microm (+/- 0.167) (P < .001). No significant changes in higher order aberrations were noted in the low and moderate hyperopia groups.
CONCLUSIONS: Hyperopic LASIK using the WaveLight ALLEGRETTO WAVE excimer laser appears to be safe and effective in the correction of low, moderate, and high hyperopia and hyperopic astigmatism.

Entities:  

Mesh:

Year:  2006        PMID: 16447935     DOI: 10.3928/1081-597X-20060101-10

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  9 in total

1.  Hyperopic Q-optimized algorithms: a theoretical study on factors influencing optical quality.

Authors:  Jose R Jiménez; Aixa Alarcón; Rosario G Anera; L Jiménez Del Barco
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

2.  One-year follow-up of patients with hyperopia undergoing photorefractive keratectomy with Allegretto WaveLight Eye Q 400.

Authors:  Behrad Shahin; Habib Ojaghi; Firouz Amani
Journal:  J Med Life       Date:  2022-04

3.  Long-Term Followup of Laser In Situ Keratomileusis for Hyperopia Using a 213 nm Wavelength Solid-State Laser.

Authors:  Carmina Franz G Quito; Archimedes Lee D Agahan; Raymond P Evangelista
Journal:  ISRN Ophthalmol       Date:  2013-03-03

4.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

5.  Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200).

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-04-03

6.  Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-02-15

7.  Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2012-06-12

8.  Comparison of corneal biomechanics after myopic small-incision lenticule extraction compared to LASIK: an ex vivo study.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2018-01-25

9.  Treatment of moderate-to-high hyperopia with the WaveLight Allegretto 400 and EX500 excimer laser systems.

Authors:  Manoj Motwani; Ronald Pei
Journal:  Clin Ophthalmol       Date:  2017-05-24