Ultrasensitive quantitative HIV-1 p24 antigen assay adapted to dried plasma spots to improve treatment monitoring in low-resource settings.

Marlyse C Knuchel1, Zuzana Tomasik, Roberto F Speck, Ruedi Lüthy, Jörg Schüpbach.   

Abstract

BACKGROUND: Our group has previously developed a quantitative and ultrasensitive HIV-1 p24 antigen assay that is inexpensive, easy-to-perform, and can be carried out in low-resource settings. Since antiretroviral therapies are becoming more accessible in resource-constrained countries, methods to assess HIV-1 viraemia are urgently needed to achieve a high standard of care in HIV-1 management.
OBJECTIVES: To adapt our quantitative assay to dried plasma spots (DPS), in order to further simplify this test and make it more accessible to resource-constrained countries. STUDY
DESIGN: DPS from 47 HIV-seropositive, treated or untreated adult individuals and 30 healthy individuals were examined.
RESULTS: A specificity of 100% was observed when p24 antigen was measured using DPS, and no differences of p24 concentration could be seen between DPS and venous plasma. The correlation between DPS and venous plasma p24 was excellent (R=0.93, CI(95%)=0.88-0.96, p<0.0001). Similarly, p24 antigen concentrations using DPS were well correlated with RNA viral load (R=0.53, CI(95%)=0.27-0.72, p=0.0002).
CONCLUSIONS: This quantitative p24 antigen test has similar sensitivity and specificity using DPS and venous plasma, and has the potential to improve health care delivery to HIV-affected individuals in resource-constrained countries.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16431154     DOI: 10.1016/j.jcv.2005.12.005

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  6 in total

1.  Diagnosis of human immunodeficiency virus type 1 infection in infants by use of dried blood spots and an ultrasensitive p24 antigen assay.

Authors:  Ada Cachafeiro; Gayle G Sherman; Annette H Sohn; Consuelo Beck-Sague; Susan A Fiscus
Journal:  J Clin Microbiol       Date:  2008-12-10       Impact factor: 5.948

2.  Analysis of the optimal cut-point for HIV-p24 antigen testing to diagnose HIV infection in HIV-exposed children from resource-constrained settings.

Authors:  M Tamhane; B Gautney; C Shiu; N Segaren; L Jeannis; C Eustache; Y Simeon-Fadois; Y H Chen; D De; S Irivinti; P Tamma; C B Thompson; S Khamadi; G K Siberry; D Persaud
Journal:  J Clin Virol       Date:  2011-02-16       Impact factor: 3.168

3.  Dried-plasma transport using a novel matrix and collection system for human immunodeficiency virus and hepatitis C virus virologic testing.

Authors:  R M Lloyd; D A Burns; J T Huong; R L Mathis; M A Winters; M Tanner; A De La Rosa; B Yen-Lieberman; W Armstrong; A Taege; D R McClernon; J L Wetshtein; Brian M Friedrich; Monique R Ferguson; William O'Brien; P M Feorino; M Holodniy
Journal:  J Clin Microbiol       Date:  2009-03-25       Impact factor: 5.948

4.  Detection of HIV-1 p24 antigen in patients with varying degrees of viremia using an ELISA with a photochemical signal amplification system.

Authors:  Simon Bystryak; Chitrangada Acharya
Journal:  Clin Chim Acta       Date:  2016-03-03       Impact factor: 3.786

5.  Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots.

Authors:  Mark M Manak; Holly R Hack; Ashley L Shutt; Brook A Danboise; Linda L Jagodzinski; Sheila A Peel
Journal:  J Clin Microbiol       Date:  2018-09-25       Impact factor: 5.948

Review 6.  HIV-1 viral load assays for resource-limited settings.

Authors:  Susan A Fiscus; Ben Cheng; Suzanne M Crowe; Lisa Demeter; Cheryl Jennings; Veronica Miller; Richard Respess; Wendy Stevens
Journal:  PLoS Med       Date:  2006-10       Impact factor: 11.069

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.