Literature DB >> 16428974

Advances in clinical 3-tesla neuroimaging.

Val M Runge, Robert S Case, Harold L Sonnier.   

Abstract

Three-tesla magnetic resonance (MR) imaging represents one of the major forefronts of diagnostic neuroradiology today. Heat deposition, changes in T1 relaxation rates, susceptibility differences, and greater inherent sensitivity to motion artifacts represent challenges to clinical implementation. However, the situation appears remarkably similar to that encountered almost 15 years ago as the field of MR transitioned from 0.3-0.6 T to 1.5 T units. Current-generation 3 T MR units already provide markedly improved imaging of the brain as compared with 1.5 T units. This is illustrated in the article that follows, together with many of the advanced techniques now available and in the pipeline to deal with the difficulties inherent at 3 T.

Mesh:

Year:  2006        PMID: 16428974     DOI: 10.1097/01.rli.0000185877.91066.01

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

Review 1.  Update on neuroimaging phenotypes of mid-hindbrain malformations.

Authors:  Patrice Jissendi-Tchofo; Mariasavina Severino; Béatrice Nguema-Edzang; Cissé Toure; Gustavo Soto Ares; Anthony James Barkovich
Journal:  Neuroradiology       Date:  2014-10-23       Impact factor: 2.804

2.  Comparison of spin-echo T1- and T2-weighted and gradient-echo T1-weighted images at 3T in evaluating very preterm neonates at term-equivalent age.

Authors:  B Sarikaya; A M McKinney; B Spilseth; C L Truwit
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-06       Impact factor: 3.825

3.  Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla.

Authors:  Jaco J M Zwanenburg; Jeroen Hendrikse; Fredy Visser; Taro Takahara; Peter R Luijten
Journal:  Eur Radiol       Date:  2009-10-03       Impact factor: 5.315

4.  Enhancement pattern of the normal facial nerve at 3.0 T temporal MRI.

Authors:  H S Hong; B-H Yi; J-G Cha; S-J Park; D H Kim; H K Lee; J-D Lee
Journal:  Br J Radiol       Date:  2009-06-22       Impact factor: 3.039

5.  Follow-up of coiled cerebral aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography.

Authors:  N Anzalone; F Scomazzoni; M Cirillo; C Righi; F Simionato; M Cadioli; A Iadanza; M A Kirchin; G Scotti
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-12       Impact factor: 3.825

  5 in total