The Laryngeal Mask (LMA) Unique and the Cobra Perilaryngeal Airway (PLA) are single-use supraglottic devices. There are no published studies comparing these devices during spontaneous ventilation. We compared the LMA Unique and the Cobra PLA with respect to 1) ventilatory variables during spontaneous ventilation, 2) time to achieve an effective airway, 3) airway intervention requirements, 4) cuff seal pressures, 5) fiberoptic score, and 6) perioperative adverse events. Eighty adult ASA physical status I-II patients undergoing general anesthesia for minor routine surgery were randomly allocated to LMA Unique or PLA Cobra for airway management. No statistically significant differences were found between the devices with respect to inspiratory tidal volume, expiratory tidal volume, end-tidal CO2 concentration, respiratory rate, number and type of airway interventions required with placement, the fiberoptic score, and the incidence of perioperative adverse events. The oropharyngeal leak (seal) pressure was higher for the CobraPLA (27 +/- 7 versus 21 +/- 4 cm H2O; P < 0.001). The oxygen saturation was higher (98.1% +/- 1% versus 97.3% +/- 2%; P = 0.02) in the LMA group. Time of insertion was shorter for LMA (23.7 +/- 2 s versus 26.6 +/- 7 s; P = 0.02) and insertion difficulty was less for LMA (P = 0.03). As these differences were not judged to be clinically important, both devices appear to be effective in establishing an adequate airway in patients who are spontaneously breathing under general anesthesia.

Entities:  

Mesh:

Year:  2006        PMID: 16428575     DOI: 10.1213/01.ane.0000189098.57662.d6

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  7 in total

1.  Cobra perilaryngeal airway for thyroid surgery in a hypertensive patient.

Authors:  Rakesh Garg; Sanjay Verma
Journal:  J Anesth       Date:  2009-08-14       Impact factor: 2.078

2.  The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia.

Authors:  Yun Mi Choi; Su Man Cha; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Jin Yun Kim; Gill Hoi Koo; Sun Gyoo Park
Journal:  Korean J Anesthesiol       Date:  2010-05-29

3.  Comparing the Laryngeal Mask Airway, Cobra Perilaryngeal Airway and Face Mask in Children Airway Management.

Authors:  Beyza Tekin; Zehra Hatipoğlu; Mediha Türktan; Dilek Özcengiz
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-04-01

4.  Comparison of streamlined liner of the pharynx airway (SLIPA™) with the laryngeal mask airway Proseal™ for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients.

Authors:  Ashraf Abualhassan Abdellatif; Monaz Abdulrahman Ali
Journal:  Saudi J Anaesth       Date:  2011-07

5.  Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults.

Authors:  Daryl Lindsay Williams; James M Zeng; Karl D Alexander; David T Andrews
Journal:  Anesthesiol Res Pract       Date:  2012-02-29

6.  Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Authors:  Yuan Tan; Guangyou Duan; Qin Chen; Feng Chen; Hong Li
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

Review 7.  Who should be screened for primary aldosteronism? A comprehensive review of current evidence.

Authors:  Wei-Chieh Huang; Yen-Hung Lin; Vin-Cent Wu; Chen-Huan Chen; Saulat Siddique; Yook-Chin Chia; Jam Chin Tay; Guruprasad Sogunuru; Hao-Min Cheng; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2022-09       Impact factor: 2.885

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.