Shear bond strength with increasing light-guide distance from dentin.

Xiaoming Xu1, Dant A Sandras, John O Burgess.   

Abstract

BACKGROUND: In Class II composite restorations, the adhesive covering the gingival floor of the deep cavity preparation is 2 to 8 mm from the light guide and may not be adequately cured with a typical 10-second curing time.
PURPOSE: The purpose of this study was to evaluate the dentin bond strengths of resin composite when the curing light guide (quartz-tungsten-halogen light) was placed at various distances and to investigate the relationships between radiant exposure, degree of conversion, and shear bond strength.
MATERIALS AND METHODS: Single Bond (3M ESPE, St. Paul, MN, USA) was placed onto the dentin following the manufacturer's directions. Four groups of 10 teeth were cured for 20 seconds through a 0, 2.3, 4.6, or 6.9 mm spacer. Two other groups of 10 teeth were cured through a 4.6 mm spacer for 40 seconds and 60 seconds, respectively. Z100 resin composite (3M ESPE) was placed over the cured adhesive and polymerized at the same distance as the adhesive. After 24 hours of storage in water, the shear bond strengths were tested. The irradiance through each spacer was measured using a digital radiometer. The degree of conversion of the adhesive was determined by near infrared spectroscopy. The data were analyzed using analysis of variance and Tukey-B post hoc tests.
RESULTS: Dentin shear bond strengths decreased significantly with increasing distance, but they increased significantly when the curing time increased from 20 to 40 or 60 seconds. There is a linear correlation between shear bond strength, degree of conversion, and logarithm (radiant exposure).
CONCLUSION: Increasing curing time can compensate for the decreased bond strength owing to a decreased irradiance associated with increased curing distance. CLINICAL SIGNIFICANCE: Under the conditions of this study, when curing the adhesives in deep proximal boxes with a quartz-tungsten-halogen light, the curing time should be increased to 40 to 60 seconds to ensure optimal polymerization.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16426505     DOI: 10.2310/6130.2006.00007

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  9 in total

1.  Effect of mold type, diameter, and uncured composite removal method on depth of cure.

Authors:  Richard B Price; Frederick A Rueggeberg; Jessie Harlow; Braden Sullivan
Journal:  Clin Oral Investig       Date:  2015-12-03       Impact factor: 3.573

2.  Influence of irradiation distance on the mechanical performances of resin composites polymerized with high-irradiance light curing units.

Authors:  Soram Oh; Hyun Ju Kim; Hyun-Jung Kim; Sibel A Antonson; Sun-Young Kim
Journal:  Biomater Res       Date:  2022-05-20

3.  Novel F-releasing composite with improved mechanical properties.

Authors:  L Ling; X Xu; G-Y Choi; D Billodeaux; G Guo; R M Diwan
Journal:  J Dent Res       Date:  2009-01       Impact factor: 6.116

4.  Comparison of the Dentin Bond Strength of Two Self-Etch Adhesives After Prolonged Air-Drying and Additional Light-Curing.

Authors:  Pouran Samimi; Masoud Ghodrati; Farinaz Shirban; Maryam Khoroushi
Journal:  J Dent (Tehran)       Date:  2017-09

5.  Evaluation of Dual-Cure Resin Cement Polymerization under Different Types and Thicknesses of Monolithic Zirconia.

Authors:  Pinar Turkoglu; Deniz Sen
Journal:  Biomed Res Int       Date:  2019-01-09       Impact factor: 3.411

6.  Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units.

Authors:  Haifa Barakah
Journal:  Saudi Dent J       Date:  2021-06-10

7.  Morphological analysis of glass, carbon and glass/carbon fiber posts and bonding to self or dual-cured resin luting agents.

Authors:  Aloísio Oro Spazzin; Rafael Ratto de Moraes; Doglas Cecchin; Ana Paula Farina; Bruno Carlini-Júnior; Lourenço Correr-Sobrinho
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

8.  Comparison of microleakage between bulk-fill flowable and nanofilled resin-based composites.

Authors:  Eman I AlSagob; David N Bardwell; Ala O Ali; Samer G Khayat; Paul C Stark
Journal:  Interv Med Appl Sci       Date:  2018-06

9.  Effect of infection control barriers on the light output from a multi-peak light curing unit.

Authors:  Carlos José Soares; Stella Sueli Lourenço Braga; Maria Tereza Hordones Ribeiro; Richard Bengt Price
Journal:  J Dent       Date:  2020-10-19       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.