Literature DB >> 1642340

Thiopental pharmacodynamics. I. Defining the pseudo-steady-state serum concentration-EEG effect relationship.

M Bührer1, P O Maitre, O R Hung, W F Ebling, S L Shafer, D R Stanski.   

Abstract

To assess depth of anesthesia for intravenous anesthetics using clinical stimuli and observed responses, it is necessary to achieve constant serum concentrations of drug that result in constant biophase or central nervous system concentrations. The goal of this investigation was to use a computer-controlled infusion pump (CCIP) to obtain constant serum thiopental concentrations and use the electroencephalogram (EEG) as a measure of thiopental's central nervous system drug effect. The number of waves per second obtained from aperiodic waveform analysis was used as the EEG measure. A CCIP was used in six male volunteers to attain rapidly and then maintain for 6-min time periods the following pseudo-steady-state constant serum thiopental target concentrations: 10, 20, 30, and 40 micrograms/ml. The median performance error (bias) of the CCIP using 149 measurements of thiopental serum concentrations in six subjects was +5%, and the median absolute performance error (accuracy) was 16%. Following the step change in serum thiopental concentration, the EEG number of waves per second stabilized within 2-3 min and the remained constant until the target serum thiopental concentration was changed. When the constant serum thiopental concentration was plotted against the number of waves per second for each subject, a biphasic serum concentration versus EEG effect relationship was seen. This biphasic concentration:response relationship was characterized with a nonparametric pharmacodynamic model. The awake, baseline EEG was 10.6 waves/s; at peak activation the EEG was 19.1 waves/s and occurred at a serum thiopental concentration of 13.3 micrograms/ml. At a serum thiopental concentration of 31.2 micrograms/ml the EEG had slowed to 10.6 waves/s (back to baseline) and at 41.2 micrograms/ml was 50% below the baseline, awake value. Zero waves per second occurred at serum thiopental concentrations greater than 50 micrograms/ml. Using a CCIP it is possible to establish constant serum thiopental concentration rapidly and characterize the concentration versus EEG drug effect relationship.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1642340     DOI: 10.1097/00000542-199208000-00002

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  8 in total

1.  Analytical methods to differentiate similar electroencephalographic spectra: neural network and discriminant analysis.

Authors:  R A Veselis; R Reinsel; M Wronski
Journal:  J Clin Monit       Date:  1993-09

2.  Functional magnetic resonance imaging of swine brain during change in thiopental anesthesia into EEG burst-suppression level--a preliminary study.

Authors:  Minna J Mäkiranta; Jukka P T Jauhiainen; Jarkko T Oikarinen; Kalervo Suominen; Osmo Tervonen; Seppo Alahuhta; Ville Jäntti
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

3.  Age progression from vicenarians (20-29 year) to nonagenarians (90-99 year) among a population pharmacokinetic/pharmacodynamic (PopPk-PD) covariate analysis of propofol-bispectral index (BIS) electroencephalography.

Authors:  Ashraf A Dahaba; Zhaoyang Xiao; Xiaoling Zhu; Hailong Dong; Lize Xiong; Peter Rehak; Sieglinde Zelzer; Kun Wang; Gilbert Reibnegger
Journal:  J Pharmacokinet Pharmacodyn       Date:  2020-02-25       Impact factor: 2.745

4.  Haemodynamic and EEG changes during rapid-sequence induction of anaesthesia.

Authors:  N Kanaya; M Nakayama; S Fujita; A Namiki
Journal:  Can J Anaesth       Date:  1994-08       Impact factor: 5.063

5.  EEG bispectrum predicts movement during thiopental/isoflurane anesthesia.

Authors:  P S Sebel; S M Bowles; V Saini; N Chamoun
Journal:  J Clin Monit       Date:  1995-03

Review 6.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

7.  Chaos analysis of EEG during isoflurane-induced loss of righting in rats.

Authors:  M B MacIver; Brian H Bland
Journal:  Front Syst Neurosci       Date:  2014-10-16

8.  How to monitor thiopental administration in the intensive care unit for refectory status epilepticus or intracranial hypertension?

Authors:  Erika Dabricot; Inès Seqat; Frédéric Dailler; Sylvain Rheims; Sebastien Boulogne; Baptiste Balança
Journal:  Crit Care       Date:  2021-12-17       Impact factor: 9.097

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.