Maintenance of graft compression in the adult cervical spine.

Ciaran Bolger1, Maurice Bourlion, Xavier Leroy, Dominique Petit, Gerard Vanacker, Linda McEvoy, Jabir Nagaria.   

Abstract

It is generally advised that the graft inserted in adult cervical spine should be pre-loaded with a compressive force or that the screws are inserted in a divergent orientation, in order to maximise compression and the chance of graft incorporation (Truumees et al. in Spine 28:1097-1102, 2003). However, there is little evidence that a compressive force is maintained once the force applicator has been removed, or that the divergent screws enhance compression. This study compared the maintenance of applied pre-load force, across cervical spine graft, between standard anterior plating technique with pre-load and divergent screws and a novel plate technique, which allows its application prior to removal of the force applicator. Six intact adult cadaveric human cervical spines were exposed by standard surgical technique. A Casper type distracter was inserted across the disc space of interest, the disc was removed. In 14 experiments, following the disc removal, an autologous iliac crest bone graft was inserted under distraction, together with a strain gauge pressure transducer. A resting output from the transducer was recorded. The voltage output has a linear relationship with compressive force. A standardised compressive force was applied across the graft through the "Casper type" distracter/compressor (7.5 kg, torque). The pre-load compressive force was measured using a torque drill. Then two different procedures were used in order to compare the final applied strain on the bone graft. In eight experiments (procedure 1), the "Casper type" distracter/compressor was removed and a standard anterior cervical plate with four divergent screws was inserted. In six experiments (procedure 2), a novel plate design was inserted prior to removal of the distracter/compressor, which is not possible with the standard plate design. A final compressive force across the graft was measured. For the standard plate construct (procedure 1), the applied compression force is significantly greater than resting (SO/SC)--P=0.01, but the compression force is not maintained once the compressor is removed (SO/SR)--P=0.27. Final bone graft compression after plate insertion is not significantly different to the resting state (SO/SF)--P=0.16 (Wilcoxon's sign test for paired observation). Application of the plate tended to offload the graft; the final compressive force is 170+/-100% less than the resting force. None of the applied force was maintained (mean 9.5+/-8.8%). For the new plate (procedure 2), the end compressive force (SF) measured across the graft was greater than the resting force (SO) (P<0.001). Further, the novel plate application increased the compressive force on the graft by 712+/-484%. The final bone graft compression using a novel plate, which allows its application prior to removal of the force applicator, is significant (SO/SF)--P=0.01. Here, 77+/-10% of the applied pre-load was maintained. The difference between the plates is significant (P<0.001). Conclusions are as follows: (1) Applied pre-load is not maintained across a graft once the force applicator is removed. (2) Divergent screws with a plate do not compress graft and rather tend to offload it. (3) Compressive force may be maintained if the plate is applied prior to the force applicator removal.

Entities:  

Mesh:

Year:  2006        PMID: 16421744      PMCID: PMC3233962          DOI: 10.1007/s00586-005-0054-z

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  17 in total

1.  The effect of cervical plating on single-level anterior cervical discectomy and fusion.

Authors:  J C Wang; P W McDonough; K Endow; L E Kanim; R B Delamarter
Journal:  J Spinal Disord       Date:  1999-12

2.  Effects of a cervical compression plate on graft forces in an anterior cervical discectomy model.

Authors:  Eeric Truumees; Constantine K Demetropoulos; King H Yang; Harry N Herkowitz
Journal:  Spine (Phila Pa 1976)       Date:  2003-06-01       Impact factor: 3.468

3.  The anterior approach for removal of ruptured cervical disks.

Authors:  R B CLOWARD
Journal:  J Neurosurg       Date:  1958-11       Impact factor: 5.115

4.  A biomechanical evaluation of graft loading characteristics for anterior cervical discectomy and fusion. A comparison of traditional and reverse grafting techniques.

Authors:  J C Wang; D Zou; H Yuan; J Yoo
Journal:  Spine (Phila Pa 1976)       Date:  1998-11-15       Impact factor: 3.468

5.  Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model.

Authors:  J D Clausen; T C Ryken; V C Traynelis; P D Sawin; F Dexter; V K Goel
Journal:  J Neurosurg       Date:  1996-06       Impact factor: 5.115

6.  Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws.

Authors:  T C Ryken; J D Clausen; V C Traynelis; V K Goel
Journal:  J Neurosurg       Date:  1995-08       Impact factor: 5.115

7.  Anterior cervical discectomy, fusion, and plating. A comparative animal study.

Authors:  T A Zdeblick; M E Cooke; D Wilson; D N Kunz; R McCabe
Journal:  Spine (Phila Pa 1976)       Date:  1993-10-15       Impact factor: 3.468

8.  One-stage internal fixation and anterior fusion in complex cervical spinal disorders.

Authors:  F G Johnston; H A Crockard
Journal:  J Neurosurg       Date:  1995-02       Impact factor: 5.115

9.  Subtotal vertebrectomy and spinal fusion for cervical spondylotic myelopathy.

Authors:  K Hanai; F Fujiyoshi; K Kamei
Journal:  Spine (Phila Pa 1976)       Date:  1986-05       Impact factor: 3.468

10.  Anterior cervical fusion and Caspar plate stabilization for cervical trauma.

Authors:  W Caspar; D D Barbier; P M Klara
Journal:  Neurosurgery       Date:  1989-10       Impact factor: 4.654

View more
  1 in total

1.  Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

Authors:  Antonius Pizanis; Jörg H Holstein; Felix Vossen; Markus Burkhardt; Tim Pohlemann
Journal:  BMC Musculoskelet Disord       Date:  2013-08-26       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.