Literature DB >> 16420535

Measurement of the mechanical properties of the skin using the suction test.

Fouad Khatyr1, Claude Imberdis, Daniel Varchon, Jean-Michel Lagarde, Gwendal Josse.   

Abstract

INTRODUCTION: The suction test is commonly used to study the mechanical properties of human skin in vivo. The unevenness of the stress fields complicates obtaining the intrinsic mechanical parameters of the skin in vivo because the values of the local stresses and deformations cannot be calculated directly from the displacements and forces applied by the test apparatus. In general, users only take into account the negative pressure applied and the elevation of the dome of skin drawn up in order to deduce the properties of the skin. This method has the major disadvantage of being dependent on the experimental conditions used: in particular, the size of the suction cup and the negative pressure applied. Here, we propose a full mechanical study of the test to provide rigorous results. We compare the frequently used geometric method (making the thin plate hypothesis), Timoshenko's method (which can take greater plate thicknesses into account) and finally various results obtained by the finite elements (FE) technique.
METHODS: The suction test was modelled by FE with large displacements and large deformations both for orthotropic and isotropic plates. The results obtained in the elastic domain for various values of Young's modulus and of applied negative pressure were used as references and were compared with methods using analytical relationships.
RESULTS: The geometric method generally used in the interpretation of suction tests gives results, which in certain configurations, are very different from those obtained by FE. The method of Timoshenko is suited to thick plates 'in contact' or embedded round the edge, the elevation of the dome and the tension and flexion stresss are analytically accessible through relationships involving four constants that are dependent on the limit conditions. Comparison with the FE results enabled the optimisation of the coefficients to adapt the relationships to the particular conditions of the suction trials.
CONCLUSION: We showed the limits of the geometrical method and proposed a solution, which while remaining simple to use, gives results that are closer to reality both for the calculation of the modulus and for the determination of the state of the stresses obtained.

Entities:  

Mesh:

Year:  2006        PMID: 16420535     DOI: 10.1111/j.0909-725X.2006.00126.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  4 in total

1.  Development of compression-controlled low-level laser probe system: towards clinical application.

Authors:  Changmin Yeo; Taeyoon Son; Junghwan Park; Young-Heum Lee; Kiwoon Kwon; J Stuart Nelson; Byungjo Jung
Journal:  Lasers Med Sci       Date:  2010-09       Impact factor: 3.161

2.  Viscoelastic response of human skin to low magnitude physiologically relevant shear.

Authors:  Brian Holt; Anubhav Tripathi; Jeffrey Morgan
Journal:  J Biomech       Date:  2008-07-30       Impact factor: 2.712

3.  Dynamic viscoelastic models of human skin using optical elastography.

Authors:  Steven P Kearney; Altaf Khan; Zoujun Dai; Thomas J Royston
Journal:  Phys Med Biol       Date:  2015-08-25       Impact factor: 3.609

4.  Needleless administration of advanced therapies into the skin via the appendages using a hypobaric patch.

Authors:  Faiza Benaouda; Ricardo Inacio; Chui Hua Lim; Haeeun Park; Thomas Pitcher; Mohamed A Alhnan; Mazen M S Aly; Khuloud T Al-Jamal; Ka-Lung Chan; Rikhav P Gala; Daniel Sebastia-Saez; Liang Cui; Tao Chen; Julie Keeble; Stuart A Jones
Journal:  Proc Natl Acad Sci U S A       Date:  2022-04-28       Impact factor: 12.779

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.