Resolving repeatedly borderline results of Hybrid Capture 2 HPV DNA Test using polymerase chain reaction and genotyping.

Katja Seme1, Kristina Fujs, Bostjan J Kocjan, Mario Poljak.   

Abstract

The Hybrid Capture 2 HPV DNA Test (hc2) (Digene Corporation, Gaithersburg, MD) is at present the only FDA approved assay for routine detection of human papillomavirus (HPV) infections. A significant analytical inaccuracy of the hc2 near to cut-off was reported recently. To address this problem, 240 samples with repeatedly borderline/equivocal/indeterminate hc2 results (samples with repeated RLU/CO values between 0.4 and 4.0) were tested using the PGMY09/PGMY11 consensus PCR and genotyping in order to resolve their high-risk HPV status. All PGMY09/PGMY11 PCR negative samples were tested in addition using CPI/IIg consensus PCR. A false negative rate of 11.3% and false positive rate of 19.1% were recorded in the samples with repeatedly borderline hc2 results. The corresponding hc2 false reactivity rates in 95 samples selected at random which were clearly hc2 negative (samples with RLU/CO values less than 0.4) and 124 samples selected at random which were clearly hc2 positive (samples with RLU/CO values more than 4.0) were 4.2% and 5.6%, respectively. The proportion of hc2 false reactivity increased with proximity to the hc2 cut-off value. According to the results of the present study, the introduction of an hc2 grey-zone and retesting of samples with repeatedly borderline hc2 results by an alternate HPV detection method, such as the PGMY09/PGMY11 consensus PCR and genotyping, is recommended.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16417931     DOI: 10.1016/j.jviromet.2005.12.004

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  7 in total

1.  Clinical impact of the analytical specificity of the hybrid capture 2 test: data from the New Technologies for Cervical Cancer (NTCC) study.

Authors:  Anna Gillio-Tos; Laura De Marco; Francesca Maria Carozzi; Annarosa Del Mistro; Salvatore Girlando; Elena Burroni; Helena Frayle-Salamanca; Paolo Giorgi Rossi; Paola Pierotti; Guglielmo Ronco
Journal:  J Clin Microbiol       Date:  2013-06-26       Impact factor: 5.948

2.  Comparison of clinical and analytical performance of the Abbott Realtime High Risk HPV test to the performance of hybrid capture 2 in population-based cervical cancer screening.

Authors:  Mario Poljak; Anja Ostrbenk; Katja Seme; Veronika Ucakar; Peter Hillemanns; Eda Vrtacnik Bokal; Nina Jancar; Irena Klavs
Journal:  J Clin Microbiol       Date:  2011-03-23       Impact factor: 5.948

3.  Human papillomavirus genotype specificity of hybrid capture 2 low-risk probe cocktail.

Authors:  Mario Poljak; Bostjan J Kocjan; Anja Kovanda; Maja M Lunar; Snjezana Zidovec Lepej; Ana Planinic; Katja Seme; Adriana Vince
Journal:  J Clin Microbiol       Date:  2009-06-03       Impact factor: 5.948

4.  Development and evaluation of a PCR and mass spectroscopy (PCR-MS)-based method for quantitative, type-specific detection of human papillomavirus.

Authors:  Divya A Patel; Yang-Jen Shih; Duane W Newton; Claire W Michael; Paul A Oeth; Michael D Kane; Anthony W Opipari; Mack T Ruffin; Linda M Kalikin; David M Kurnit
Journal:  J Virol Methods       Date:  2009-05-03       Impact factor: 2.014

5.  Clinical relevance of the borderline results of the Hybrid Capture 2 High-Risk HPV DNA assay with cervical samples collected in Specimen Transport Medium.

Authors:  Jerneja Varl; Urska Ivanus; Ziva Pohar Marinsek; Tine Jerman; Anja Ostrbenk Valencak; Mario Poljak; Veronika Kloboves Prevodnik
Journal:  Radiol Oncol       Date:  2019-09-24       Impact factor: 2.991

6.  Comparison of the AdvanSure human papillomavirus screening real-time PCR, the Abbott RealTime High Risk human papillomavirus test, and the Hybrid Capture human papillomavirus DNA test for the detection of human papillomavirus.

Authors:  Yusun Hwang; Miae Lee
Journal:  Ann Lab Med       Date:  2012-04-18       Impact factor: 3.464

7.  A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge.

Authors:  Rui Wang; Jing Wu; Xiaodong He; Peng Zhou; Zuojun Shen
Journal:  Micromachines (Basel)       Date:  2021-03-04       Impact factor: 2.891

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.