Estimation of arterial carbon dioxide by end-tidal and transcutaneous PCO2 measurements in ventilated children.

Y Sivan1, M K Eldadah, T E Cheah, C J Newth.   

Abstract

Simultaneous measurements of arterial, end-tidal, and transcutaneous carbon dioxide (PaCO2, PetCO2, PtcCO2, respectively) were obtained in 134 children receiving mechanical ventilation (ages, 2 days to 16 years; mean, 2.5 years). The mean +/- SD PetCO2 bias (PaCO2 - PetCO2) was 3.4 +/- 6.6 mmHg. When the PetCO2 bias was plotted against the PaO2/PAO2 ratio, a change in the scatter was obvious at about 0.3. The PetCO2 bias for patients with PaO2/PAO2 under 0.3 was 7.8 +/- 7.3 mmHg compared to 0 +/- 3.4 in patients with PaO2/PAO2 above 0.3 (P less than 0.001). PetCO2 differed significantly from PaCO2 (P less than 0.001) only for patients with PaO2/PAO2 under 0.3. The slope (PaCO2 versus PetCO2) for these patients was 1.59, while the slope for patients with PaO2/PAO2 above 0.3 coincided with the line of identity (1.00). The mean +/- SD PtcCO2 bias (PaCO2 - PtcCO2) was -1.3 +/- 7.2 mmHg. Skin perfusion was recorded at the area close to the transcutaneous CO2 monitor electrode and was defined as normal when capillary refill was below 3 seconds. The PtcCO2 bias for patients with normal skin perfusion was -0.2 +/- 5.4 mmHg (P = 0.73) compared to -4.1 +/- 9.9 for patients with decreased skin perfusion (P = 0.01). The slope of PtcCO2 against PaCO2 was closer to identity in patients with normal skin perfusion (1.17) than in patients where it was decreased (slope, 1.40). We suggest that PaCO2 estimation by both PetCO2 and PtcCO2 is sufficiently precise and reliable for clinical use in critically ill children. Certain limitations stem from the nature of the techniques.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1641271     DOI: 10.1002/ppul.1950120305

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  12 in total

Review 1.  Role of lung function testing in the management of mechanically ventilated infants.

Authors:  A Schibler; U Frey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

Review 2.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

3.  Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.

Authors:  D G Tingay; M J Stewart; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-04-29       Impact factor: 5.747

4.  Relationship between end-tidal carbon dioxide and arterial carbon dioxide in critically ill patients on mechanical ventilation: A cross-sectional study.

Authors:  Jinrong Wang; Jianjun Zhang; Yajing Liu; Huimian Shang; Li Peng; Zhaobo Cui
Journal:  Medicine (Baltimore)       Date:  2021-08-20       Impact factor: 1.817

5.  End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error.

Authors:  R H Friesen; M Alswang
Journal:  J Clin Monit       Date:  1996-03

6.  Detection of carbon dioxide thresholds using low-flow sidestream capnography in ventilated preterm infants.

Authors:  Emmanuel Lopez; Sophie Grabar; Alexandre Barbier; Baruch Krauss; Pierre-Henri Jarreau; Guy Moriette
Journal:  Intensive Care Med       Date:  2009-11       Impact factor: 17.440

7.  Agreement of Mixed Venous Carbon Dioxide Tension (PvCO2) and Transcutaneous Carbon Dioxide (PtCO2) Measurements in Ventilated Infants.

Authors:  Sinan Uslu; Ali Bulbul; Mesut Dursun; Umut Zubarioglu; Ebru Turkoglu; Omer Guran
Journal:  Iran J Pediatr       Date:  2015-01-19       Impact factor: 0.364

8.  Correlation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically ventilated patients.

Authors:  Ebrahim Razi; Gholam Abbass Moosavi; Keivan Omidi; Ashkan Khakpour Saebi; Armin Razi
Journal:  Arch Trauma Res       Date:  2012-08-21

9.  Comparison of arterial CO2 estimation by end-tidal and transcutaneous CO2 measurements in intubated children and variability with subject related factors.

Authors:  Muhterem Duyu; Yasemin Mocan Çağlar; Zeynep Karakaya; Mine Usta Aslan; Seyhan Yılmaz; Aslı Nur Ören Leblebici; Anıl Doğan Bektaş; Meral Bahar; Meryem Nihal Yersel
Journal:  J Clin Monit Comput       Date:  2020-07-27       Impact factor: 2.502

10.  Comparing the novel microstream and the traditional mainstream method of end-tidal CO2 monitoring with respect to PaCO2 as gold standard in intubated critically ill children.

Authors:  Muhterem Duyu; Anıl Dogan Bektas; Zeynep Karakaya; Meral Bahar; Aybuke Gunalp; Yasemin Mocan Caglar; Meryem Nihal Yersel; Ozlem Bozkurt
Journal:  Sci Rep       Date:  2020-12-16       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.