AIMS: The aim of this study was to develop a 5'-nuclease polymerase chain reaction (PCR) for the rapid detection and quantification of Listeria monocytogenes. METHODS AND RESULTS: Specific primers and a fluorogenic probe were designed, which target a specific sequence of the actA gene encoding for a protein involved in the actin filament assembly. The PCR system was highly sensitive and specific for L. monocytogenes (inclusivity, 100%; exclusivity, 100%), which was determined using 46 L. monocytogenes and 28 non-L. monocytogenes strains. Detection limits of 10(4) cfu ml(-1) after 35 cycles and 10(2) cfu ml(-1) after 45 cycles were achieved by PCR in both real-time and end-point fluorescence measurement modes. Linear calibration lines were obtained in the range from 10(2) to 10(9) cfu ml(-1) for three L. monocytogenes strains in real-time PCR with 45 cycles. CONCLUSIONS: The developed 5'-nuclease PCR of the actA gene provides a new target for the rapid detection and quantification of L. monocytogenes. SIGNIFICANCE AND IMPACT OF THE STUDY: In conjunction with enrichment or with an appropriate quantitative sample preparation technique, the method is suitable for food safety applications.
AIMS: The aim of this study was to develop a 5'-nuclease polymerase chain reaction (PCR) for the rapid detection and quantification of Listeria monocytogenes. METHODS AND RESULTS: Specific primers and a fluorogenic probe were designed, which target a specific sequence of the actA gene encoding for a protein involved in the actin filament assembly. The PCR system was highly sensitive and specific for L. monocytogenes (inclusivity, 100%; exclusivity, 100%), which was determined using 46 L. monocytogenes and 28 non-L. monocytogenes strains. Detection limits of 10(4) cfu ml(-1) after 35 cycles and 10(2) cfu ml(-1) after 45 cycles were achieved by PCR in both real-time and end-point fluorescence measurement modes. Linear calibration lines were obtained in the range from 10(2) to 10(9) cfu ml(-1) for three L. monocytogenes strains in real-time PCR with 45 cycles. CONCLUSIONS: The developed 5'-nuclease PCR of the actA gene provides a new target for the rapid detection and quantification of L. monocytogenes. SIGNIFICANCE AND IMPACT OF THE STUDY: In conjunction with enrichment or with an appropriate quantitative sample preparation technique, the method is suitable for food safety applications.
Authors: Ariuntuya Tserendorj; Alfredo J Anceno; Eric R Houpt; Crystal R Icenhour; Orntipa Sethabutr; Carl S Mason; Oleg V Shipin Journal: Ecohealth Date: 2011-12-07 Impact factor: 3.184
Authors: Avelino Alvarez-Ordóñez; Dara Leong; Ciara A Morgan; Colin Hill; Cormac G M Gahan; Kieran Jordan Journal: Biomed Res Int Date: 2015-10-12 Impact factor: 3.411