Literature DB >> 16411804

Detection of hearing loss using 2f2-f1 and 2f1-f2 distortion-product otoacoustic emissions.

Tracy S Fitzgerald1, Beth A Prieve.   

Abstract

Although many distortion-product otoacoustic emissions (DPOAEs) may be measured in the ear canal in response to 2 pure tone stimuli, the majority of clinical studies have focused exclusively on the DPOAE at the frequency 2f1-f2. This study investigated another DPOAE, 2f2-f1, in an attempt to determine the following: (a) the optimal stimulus parameters for its clinical measurement and (b) its utility in differentiating between normal-hearing and hearing-impaired ears at low-to-mid frequencies (<or=2,000 Hz) when measured either alone or in conjunction with the 2f1-f2 DPOAE. Two experiments were conducted. In Experiment 1, the effects of primary level, level separation, and frequency separation (f2/f1) on 2f2-f1 DPOAE level were evaluated in normal-hearing ears for low-to-mid f2 frequencies (700-2,000 Hz). Moderately high-level primaries (60-70 dB SPL) presented at equal levels or with f2 slightly higher than f1 produced the highest 2f2-f1 DPOAE levels. When the f2/f1 ratio that produced the highest 2f2-f1 DPOAE levels was examined across participants, the mean optimal f2/f1 ratio across f2 frequencies and primary level separations was 1.08. In Experiment 2, the accuracy with which DPOAE level or signal-to-noise ratio identified hearing status at the f2 frequency as normal or impaired was evaluated using clinical decision analysis. The 2f2-f1 and 2f1-f2 DPOAEs were measured from both normal-hearing and hearing-impaired ears using 2 sets of stimulus parameters: (a) the traditional parameters for measuring the 2f1-f2 DPOAE (f2/f1 = 1.22; L1, L2 = 65, 55 dB SPL) and (b) the new parameters that were deemed optimal for the 2f2-f1 DPOAE in Experiment 1 (f2/f1 = 1.073, L1 and L2 = 65 dB SPL). Identification of hearing status using 2f2-f1 DPOAE level and signal-to-noise ratio was more accurate when the new stimulus parameters were used compared with the results achieved when the 2f2-f1 DPOAE was recorded using the traditional parameters. However, identification of hearing status was less accurate for the 2f2-f1 DPOAE measured using the new parameters than for the 2f1-f2 DPOAE measured using the traditional parameters. No statistically significant improvements in test performance were achieved when the information from the 2 DPOAEs was combined, either by summing the DPOAE levels or by using logistic regression analysis.

Entities:  

Mesh:

Year:  2005        PMID: 16411804     DOI: 10.1044/1092-4388(2005/082)

Source DB:  PubMed          Journal:  J Speech Lang Hear Res        ISSN: 1092-4388            Impact factor:   2.297


  4 in total

1.  Do "optimal" conditions improve distortion product otoacoustic emission test performance?

Authors:  Benjamin J Kirby; Judy G Kopun; Hongyang Tan; Stephen T Neely; Michael P Gorga
Journal:  Ear Hear       Date:  2011 Mar-Apr       Impact factor: 3.570

2.  Reliability and clinical test performance of cochlear reflectance.

Authors:  Daniel M Rasetshwane; Sara E Fultz; Judy G Kopun; Michael P Gorga; Stephen T Neely
Journal:  Ear Hear       Date:  2015-01       Impact factor: 3.570

3.  DPOAE level mapping for detecting noise-induced cochlear damage from short-duration music exposures.

Authors:  Jay C Buckey; Abigail M Fellows; Odile H Clavier; Lindsay V Allen; Chris A Brooks; Jesse A Norris; Jiang Gui; Deanna K Meinke
Journal:  Noise Health       Date:  2015 Sep-Oct       Impact factor: 0.867

4.  The Immediate and Long-Term Impact of Military Aircraft Noise on Hearing: A Cross-Sectional Comparison of Fighter Pilots and Ground Staff.

Authors:  Chao-Yin Kuo; Chia-Lien Hung; Hsin-Chien Chen; Cheng-Ping Shih; Rou-Huei Lu; Chen-Wai Chen; Li-Wen Hung; Yi-Chun Lin; Hang-Kang Chen; Da-Ming Chu; Yuan-Yung Lin; Yueh-Chun Chen; Chih-Hung Wang
Journal:  Int J Environ Res Public Health       Date:  2021-03-14       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.