Literature DB >> 16410236

Computer-assisted femoral head resurfacing.

Antony J Hodgson1, Kevin B Inkpen, Mark Shekhman, Carolyn Anglin, Jerome Tonetti, Bassam A Masri, Clive P Duncan, Donald S Garbuz, Nelson V Greidanus.   

Abstract

Femoral head resurfacing is re-emerging as a surgical option for younger patients who are not yet candidates for total hip replacement. However, this procedure is more difficult than total hip replacement, and the mechanical jigs typically used to align the implant produce significant variability in implant placement and take a significant amount of time to position properly. We propose that a computer-assisted surgical (CAS) technique could reduce implant variability with little or no increase in operative time. We describe a new CAS technique for this procedure and demonstrate in a cadaver study of five paired femurs that the CAS technique in the hands of a novice surgeon markedly reduced the varus/valgus variability of the implant relative to the pre-operative plan (2 degrees standard deviation for CAS versus 5 degrees for a mechanical jig operated by an expert surgeon). We also show that the mechanical jig resulted in significantly retroverted implant placement. There was no significant difference in operative time between the two techniques.

Entities:  

Mesh:

Year:  2005        PMID: 16410236     DOI: 10.3109/10929080500379440

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  7 in total

1.  [Imageless computer navigation of hip resurfacing arthroplasty].

Authors:  Christoph Schnurr; Jochen Nessler; Jürgen Koebke; Joern William Michael; Peer Eysel; Dietmar Pierre König
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

2.  Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy.

Authors:  C Schnurr; J W P Michael; P Eysel; D P König
Journal:  Int Orthop       Date:  2007-12-22       Impact factor: 3.075

3.  Component alignment in hip resurfacing using computer navigation.

Authors:  Chris Bailey; Rehan Gul; Mark Falworth; Steven Zadow; Roger Oakeshott
Journal:  Clin Orthop Relat Res       Date:  2008-10-30       Impact factor: 4.176

4.  Computer-assisted hip resurfacing planning using Lie group shape models.

Authors:  Mohamed S Hefny; John F Rudan; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-05-01       Impact factor: 2.924

5.  Use of patient-specific templates in hip resurfacing arthroplasty: experience from sixteen cases.

Authors:  Hao Du; Xiao-xiao Tian; Tong-sen Li; Jin-sheng Yang; Ke-han Li; Guo-xian Pei; Le Xie
Journal:  Int Orthop       Date:  2013-03-02       Impact factor: 3.075

6.  Accuracy of computer-assisted navigation for femoral head resurfacing decreases in hips with abnormal anatomy.

Authors:  Rocco P Pitto; Sharif Malak; Iain A Anderson
Journal:  Clin Orthop Relat Res       Date:  2009-05-07       Impact factor: 4.176

7.  Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty.

Authors:  R P Pitto; S Malak; I A Anderson
Journal:  Int Orthop       Date:  2008-08-29       Impact factor: 3.075

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.