Literature DB >> 16410061

Incidence of instrument separation using LightSpeed rotary instruments.

Kenneth I Knowles1, Nathan B Hammond, Stephen G Biggs, Jose L Ibarrola.   

Abstract

The use of nickel-titanium rotary instrument systems has gained popularity over the past 10 years. One of these instrument systems is the LightSpeed (LightSpeed Technology, Inc, San Antonio, TX). One drawback for all nickel-titanium rotary instruments is the incidence of instrument separation. The purpose of this study was to evaluate the incidence of nonretrievable instrument separation using the LightSpeed system in a clinical setting. A total of 3543 canals were treated over a 24 month period and during that time, 46 LightSpeed instruments were separated and found to be nonretrievable, resulting in a separation rate of 1.30%. This rate was lower than previous reported studies.

Mesh:

Substances:

Year:  2006        PMID: 16410061     DOI: 10.1016/j.joen.2005.10.008

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  10 in total

1.  [Comparative study on three kinds of microtube extraction devices in vitro].

Authors:  Xin Yue; Jing Shen; Hai-Feng Zhang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-04-01

2.  Success Rate and Time for Bypassing the Fractured Segments of Four NiTi Rotary Instruments.

Authors:  Alireza Adl; Arash Shahravan; Melika Farshad; Shahab Honar
Journal:  Iran Endod J       Date:  2017

3.  Use of an intraoperative navigation system for retrieving a broken dental instrument in the mandible: a case report.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Akane Shibata; Kenichi Matsumoto; Yuka Sukegawa-Takahashi; Kyosuke Sakaida; Yoshihiko Furuki
Journal:  J Med Case Rep       Date:  2017-01-15

4.  Incidence of ProTaper Universal System Instrument Fractures - A Retrospective Clinical Study.

Authors:  Ricardo Machado; Claudemir de Souza Júnior; Matheus Felipe Colombelli; Ana Paula Picolli; Jaci Simi Junior; Leopoldo Cosme-Silva; Lucas da Fonseca Roberti Garcia; Luiz Rômulo Alberton
Journal:  Eur Endod J       Date:  2018-07-19

5.  The Effect of Multiple Autoclave Sterilization on the Cyclic Fatigue of Three Heat-Treated Nickel-Titanium Rotary Files: EdgeFile X7, Vortex Blue, and TRUShape.

Authors:  Reham Sharroufna; Mohammed Mashyakhy
Journal:  Biomed Res Int       Date:  2020-12-14       Impact factor: 3.411

6.  YouTube as an information source for instrument separation in root canal treatment.

Authors:  Yağız Özbay; Neslihan Yılmaz Çırakoğlu
Journal:  Restor Dent Endod       Date:  2021-01-12

7.  Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study.

Authors:  Liliana Machado Ruivo; Marcos de Azevedo Rios; Alexandre Mascarenhas Villela; Alexandre Sigrist de Martin; Augusto Shoji Kato; Rina Andrea Pelegrine; Ana Flávia Almeida Barbosa; Emmanuel João Nogueira Leal Silva; Carlos Eduardo da Silveira Bueno
Journal:  Restor Dent Endod       Date:  2021-09-09

8.  Surgical removal of fractured endodontic instrument in the periapex of mandibular first molar.

Authors:  Adil Gandevivala; Bandish Parekh; Gaurav Poplai; Aliya Sayed
Journal:  J Int Oral Health       Date:  2014-07

Review 9.  The Impact of Apical Patency in the Success of Endodontic Treatment of Necrotic Teeth with Apical Periodontitis: A Brief Review.

Authors:  Ricardo Machado; Carlos Henrique Ferrari; Eduardo Back; Daniel Comparin; Luiz Fernando Tomazinho; Luiz Pascoal Vansan
Journal:  Iran Endod J       Date:  2015-12-24

Review 10.  Separation of Nickel-Titanium Rotary and Reciprocating Instruments: A Mini-Review of Clinical Studies.

Authors:  Marcelo Santos Coelho; Marcos de Azevêdo Rios; Carlos Eduardo da Silveira Bueno
Journal:  Open Dent J       Date:  2018-10-25
  10 in total